Suppr超能文献

使用锥形束计算机断层扫描检测龋齿时,银汞合金修复体和操作参数对诊断准确性的影响:一项体外研究。

Effect of Amalgam Restorations and Operation Parameters on Diagnostic Accuracy of Caries Detection Using Cone Beam Computed Tomography: An In Vitro Study.

机构信息

Basic Dental Science, College of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia.

Clinical Dental Science Department, College of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia.

出版信息

Scanning. 2021 Aug 16;2021:2679012. doi: 10.1155/2021/2679012. eCollection 2021.

Abstract

This study was aimed to evaluate the diagnostic accuracy of cone beam computed tomography (CBCT) in detecting noncavitated approximal caries at different exposure parameters and to assess the impact of artifacts generated by amalgam restorations in an in vitro study. Seventy-eight approximal surfaces of extracted teeth were prepared with intentionally created noncavitated approximal caries of different depths; then, thirteen teeth with class 2 amalgam restorations were replaced with one tooth with normal surfaces in each block. CBCT volumes for all teeth were acquired using a Planmeca Promax 3D Mid imaging unit before and after placement of amalgam teeth, with different exposure parameters at low and high definition, both applying and omitting the Metal Artifact Reduction algorithm. The lesions were classified into four groups with regard to lesion extension. All teeth underwent histological analysis as gold standard. The histological examination showed that the distribution of lesions was as follows: 39.8% sound, enamel lesions of less and more than half the enamel thickness each 17.8%, and 24.6% dentin lesions. The detection sensitivity was found to be 0.972%, and specificity was found to be 0.937% for the detection of noncavitated approximal initial enamel and dentin caries. The highest diagnostic accuracy was found when using operating parameters of 90 kV, 8 mA, and high resolution (75 m) with nonamalgam teeth; all modes showed statistically significant higher AUCs than mode 2 (80 kV, 7 mA, and 75 m). However, for teeth with amalgam restorations, the highest accuracy was obtained at low resolution (200 m) with the other parameters kept the same. It could be concluded that increasing the peak voltage and current improves diagnostic accuracy for the detection of noncavitated approximal caries. Moreover, diagnostic accuracy was found to be higher upon using high spatial resolution when diagnosing caries without adjacent amalgam restorations. There is a statistically significant difference with and without amalgam with respect to all modes.

摘要

本研究旨在评估锥形束计算机断层扫描(CBCT)在不同曝光参数下检测非龋性近中面龋齿的诊断准确性,并在体外研究中评估银汞合金修复体产生的伪影的影响。将 78 个近中面牙制备成不同深度的非龋性近中面龋齿;然后,用一颗正常表面的牙齿替换每个块中具有 2 类银汞合金修复体的 13 颗牙齿。在放置银汞合金牙前后,使用 Planmeca Promax 3D Mid 成像单元获取所有牙齿的 CBCT 容积,在低和高清晰度下使用不同的曝光参数,同时应用和省略金属伪影减少算法。根据病变延伸程度,将病变分为 4 组。所有牙齿均进行组织学分析作为金标准。组织学检查显示病变分布如下:39.8%为正常,釉质层病变,釉质层厚度小于或大于一半各 17.8%,牙本质层病变 24.6%。检测非龋性近中初始釉质和牙本质龋齿的检测灵敏度为 0.972%,特异性为 0.937%。使用无银汞合金牙齿的 90 kV、8 mA 和高分辨率(75 µm)的操作参数时,诊断准确性最高;所有模式的 AUC 均明显高于模式 2(80 kV、7 mA 和 75 µm)。然而,对于具有银汞合金修复体的牙齿,在保持其他参数不变的情况下,使用低分辨率(200 µm)时可获得最高的准确性。研究结果表明,增加峰值电压和电流可提高检测非龋性近中面龋齿的诊断准确性。此外,在没有相邻银汞合金修复体的情况下,使用高空间分辨率诊断龋齿时,诊断准确性更高。所有模式都存在有统计学意义的差异。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/782c/8384543/efdcd46b7232/SCANNING2021-2679012.001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验