Kirkup L, Nichols D J, Sutherland J
Physics Department, Paisley College of Technology, Scotland.
Comput Appl Biosci. 1986 Dec;2(4):277-82. doi: 10.1093/bioinformatics/2.4.277.
We describe a simple and inexpensive demonstration of mass transport and exchange using dye clearance from a hydrodynamic model. A microcomputer was used for data acquisition and storage, non-linear least squares curve fitting, compartmental analysis and parameter estimation. The system is useful for demonstrating the indicator-dilution technique for fluid volume measurement and compartmental analysis in pharmacokinetics.