关节线等距测量在全膝关节置换术中是一种很有价值的工具。

The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty.

机构信息

Department of Trauma & Orthopaedic Surgery, Imperial College Healthcare NHS Trust, London, United Kingdom.

Imperial College London, London, United Kingdom.

出版信息

PLoS One. 2021 Sep 10;16(9):e0257325. doi: 10.1371/journal.pone.0257325. eCollection 2021.

Abstract

BACKGROUND

Preservation of joint line height is an important factor in post-operative function after Total Knee Arthroplasty (TKA). This is the first study investigating the reliability of the novel Imperial Joint Line Congruency Measurement (IJLCM) technique for the assessment of joint line height using plain radiographs.

METHODS

The reliability of two techniques used to measure joint line height on pre-operative and post-operative plain radiographs is presented. 120 patients that underwent TKA from 6 different international centres were included. Measurements were performed using each technique by two senior orthopaedic surgeons at two different timepoints (test-retest). Two undergraduate medical students performed joint line measurements using the most reproducible of the two techniques on 40 pre-operative and post-operative images to establish the reliability of the measurement technique.

RESULTS

The IJLCM demonstrated an average absolute difference of 1.83mm (CI 1.56-2.10mm) and excellent inter and intra-rater reliability between senior orthopaedic surgeons (>0.92 (CI 0.88-0.94) when measuring joint line height on plain radiographs. Overall Crohnbach's alpha over 0.92 confirmed internal consistency. Measurements performed using the control technique as previously described by Figgie et al. had an average absolute difference of 5.75mm (5.17-6.32mm). Comparison of measurements by senior orthopaedic surgeons and medical students using the IJLCM technique with ANOVA and student's t-test demonstrated acceptable agreement and inter-rater reliability of >0.92 (0.87-0.95).

CONCLUSION

This study shows excellent accuracy, precision, and reliability of the novel IJLCM technique. Furthermore, excellent agreement between senior orthopaedic surgeons and medical students when using the IJLCM could be shown. The IJLCM technique is reliable for joint line assessment.

摘要

背景

在全膝关节置换术(TKA)后,保持关节线高度是术后功能的一个重要因素。这是第一项研究,探讨了使用普通 X 线片评估关节线高度的新型帝国关节线一致性测量(IJLCM)技术的可靠性。

方法

介绍了两种用于测量术前和术后普通 X 线片上关节线高度的技术的可靠性。纳入了来自 6 个国际中心的 120 例接受 TKA 的患者。使用两种技术由两名资深骨科医生在两个不同的时间点(测试-再测试)进行测量。两名本科医学生使用两种技术中最具可重复性的技术对 40 张术前和术后图像进行关节线测量,以确定测量技术的可靠性。

结果

IJLCM 显示平均绝对差值为 1.83mm(95%置信区间为 1.56-2.10mm),高级骨科医生之间的内部和内部评分者可靠性非常好(>0.92(95%置信区间为 0.88-0.94)),用于在普通 X 线片上测量关节线高度。总体克朗巴赫α值大于 0.92 确认了内部一致性。使用以前由 Figgie 等人描述的对照技术进行的测量平均绝对差值为 5.75mm(5.17-6.32mm)。使用 ANOVA 和学生 t 检验比较高级骨科医生和医学生使用 IJLCM 技术的测量值,结果表明具有可接受的一致性和>0.92(0.87-0.95)的评分者可靠性。

结论

这项研究表明新型 IJLCM 技术具有出色的准确性、精度和可靠性。此外,还可以显示高级骨科医生和医学生使用 IJLCM 时的高度一致性。IJLCM 技术是评估关节线的可靠方法。