Department of Radiology, The Sixth Affiliated People's Hospital, Shanghai Jiao Tong University, No. 600, Yi Shan Road, Shanghai, 200233, China.
MR Application Development, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, China.
Abdom Radiol (NY). 2021 Dec;46(12):5659-5668. doi: 10.1007/s00261-021-03268-5. Epub 2021 Sep 12.
To compare advanced non-parallel transmission zoomed diffusion-weighted imaging (nonPTX zoom-DWI) to conventional DWI (conv-DWI) for the assessment of prostate cancer (PCa).
This retrospective study included 98 patients who underwent conv-DWI, nonPTX zoom-DWI, and T2-weighted imaging of the prostate. The image qualities of the two DWI sets, including the distortion of the prostate and the existence of artifacts, were evaluated. To compare the overall PCa and clinically important PCa (ciPCa) detection ability between the sets, lesions were scored using the Prostate Imaging Reporting and Data System (PI-RADS) version 2. Apparent diffusion coefficient (ADC) values of the lesions were also measured and compared. The Mann-Whitney U test was used to compare continuous variables, and the χ test was used to compare categorical variables. Two-sided P values of < 0.05 were considered significant.
Non-PTX zoom-DWI yielded significantly better image quality and image analysis reproducibility than conv-DWI (all P < 0.001). Compared with conv-ADC, nonPTX zoom-ADC showed slightly better detection performance for overall PCa (AUC: 0.827 vs. 0.797; P = 0.55) and ciPCa (AUC: 0.822 vs. 0.749; P = 0.58). At a PI-RADS score of 4 as the cutoff value for PCa prediction, nonPTX zoom-DWI showed significantly higher diagnostic efficiency for overall PCa detection (sensitivity: 87.9% vs. 72.4%; specificity: 87.5% vs. 77.5%; both P < 0.05) and ciPCa detection (sensitivity: 86.3% vs. 74.5%; specificity: 72.3% vs. 63.8%; both P ≤ 0.001).
Non-PTX zoom-DWI yields better image quality and higher PCa detection performance than Conv-DWI.
比较高级非平行传输缩放扩散加权成像(nonPTX zoom-DWI)与传统 DWI(conv-DWI)在前列腺癌(PCa)评估中的应用。
本回顾性研究纳入了 98 例接受 conv-DWI、nonPTX zoom-DWI 和前列腺 T2 加权成像的患者。评估了两种 DWI 序列的图像质量,包括前列腺变形和伪影的存在。为了比较两种方法在整体 PCa 和临床重要 PCa(ciPCa)检测能力方面的差异,使用前列腺成像报告和数据系统(PI-RADS)版本 2 对病变进行评分。还测量并比较了病变的表观扩散系数(ADC)值。使用 Mann-Whitney U 检验比较连续变量,使用 χ 检验比较分类变量。双侧 P 值<0.05 被认为具有统计学意义。
nonPTX zoom-DWI 的图像质量和图像分析可重复性明显优于 conv-DWI(均 P<0.001)。与 conv-ADC 相比,nonPTX zoom-ADC 对整体 PCa(AUC:0.827 比 0.797;P=0.55)和 ciPCa(AUC:0.822 比 0.749;P=0.58)的检测性能略有提高。在以 PI-RADS 评分 4 作为 PCa 预测的截断值时,nonPTX zoom-DWI 对整体 PCa 检测的诊断效率明显更高(敏感性:87.9%比 72.4%;特异性:87.5%比 77.5%;均 P<0.05)和 ciPCa 检测(敏感性:86.3%比 74.5%;特异性:72.3%比 63.8%;均 P≤0.001)。
nonPTX zoom-DWI 比 conv-DWI 具有更好的图像质量和更高的 PCa 检测性能。