Phys Eng Sci Med. 2021 Dec;44(4):1249-1255. doi: 10.1007/s13246-021-01059-2. Epub 2021 Sep 20.
In this study, we aim to clarify the dosimetric characteristics of a real time variable shape rubber containing tungsten (STR) as a thin bolus in 6-MV photon radiotherapy. The percentage depth doses (PDDs) and lateral dose profiles (irradiation field = 10 × 10 cm) in the water-equivalent phantom were measured and compared between no bolus, a commercial 5-mm gel bolus, and 0.5-, 1-, 2-, and 3-mm STR boluses. The characteristics of the PDDs were evaluated according to relative doses at 1 mm depth (D) and depth of maximum dose (d). To determine the distance of the shift caused by the STR bolus, the PDD value at a depth of 100 mm without a bolus was obtained. For each STR thickness, the difference between the depth corresponding to this PDD value and 100 mm was calculated. The penumbra size and width of the 50% dose were evaluated using lateral dose profiles. The D with no bolus, 5-mm gel bolus, and 0.5-, 1-, 2-, and 3-mm STR boluses were 47.6%, 91.5%, 78.2%, 86.6%, 89.3%, and 89.4%, respectively, and the respective d values were 15, 10, 13, 12, 11, and 10 mm. The shifting distance of the 0.5-, 1-, 2-, and 3-mm STR boluses were 2.7, 4.4, 4.8, and 4.9 mm, respectively. There were no differences for those in lateral dose profiles. The 1-mm-thick STR thin bolus shifted the depth dose profile by 4.4 mm and could be used as a customized bolus for photon radiotherapy.
在这项研究中,我们旨在阐明作为 6-MV 光子放射治疗中的薄束的实时可变形状含钨橡胶(STR)的剂量学特性。在水等效体模中,测量并比较了无束、商业 5-mm 凝胶束以及 0.5、1、2 和 3-mm STR 束的百分深度剂量(PDD)和侧向剂量分布(照射野=10×10 cm)。根据 1 毫米深度(D)和最大剂量深度(d)处的相对剂量评估 PDD 特性。为了确定 STR 束引起的移位距离,获得了无束时 100 毫米深度处的 PDD 值。对于每种 STR 厚度,计算该 PDD 值对应的深度与 100 毫米之间的差值。使用侧向剂量分布评估半影大小和 50%剂量的宽度。无束、5-mm 凝胶束和 0.5、1、2 和 3-mm STR 束的 D 值分别为 47.6%、91.5%、78.2%、86.6%、89.3%和 89.4%,相应的 d 值分别为 15、10、13、12、11 和 10 mm。0.5、1、2 和 3-mm STR 束的移位距离分别为 2.7、4.4、4.8 和 4.9 mm。侧向剂量分布没有差异。1 毫米厚的 STR 薄束将深度剂量分布移位 4.4 毫米,可以用作光子放射治疗的定制束。