Gatta Gianluca, Cappabianca Salvatore, La Forgia Daniele, Massafra Raffaella, Fanizzi Annarita, Cuccurullo Vincenzo, Brunese Luca, Tagliafico Alberto, Grassi Roberto
Dipartimento di Medicina di Precisione Università della Campania "Luigi Vanvitelli", 80131 Napoli, Italy.
IRCCS Istituto Tumori "Giovanni Paolo II", 70124 Bari, Italy.
J Pers Med. 2021 Aug 31;11(9):875. doi: 10.3390/jpm11090875.
In our study, we added a three-dimensional automated breast ultrasound (3D ABUS) to mammography to evaluate the performance and cancer detection rate of mammography alone or with the addition of 3D prone ABUS in women with dense breasts. Our prospective observational study was based on the screening of 1165 asymptomatic women with dense breasts who selected independent of risk factors. The results evaluated include the cancers detected between June 2017 and February 2019, and all surveys were subjected to a double reading. Mammography detected four cancers, while mammography combined with a prone Sofia system (3D ABUS) doubled the detection rate, with eight instances of cancer being found. The diagnostic yield difference was 3.4 per 1000. Mammography alone was subjected to a recall rate of 14.5 for 1000 women, while mammography combined with 3D prone ABUS resulted in a recall rate of 26.6 per 1000 women. We also observed an additional 12.1 recalls per 1000 women screened. Integrating full-field digital mammography (FFDM) with 3D prone ABUS in women with high breast density increases and improves breast cancer detection rates in a significant manner, including small and invasive cancers, and it has a tolerable impact on recall rate. Moreover, 3D prone ABUS performance results are comparable with the performance results of the supine 3D ABUS system.
在我们的研究中,我们在乳腺钼靶检查中加入了三维自动乳腺超声(3D ABUS),以评估单纯乳腺钼靶检查或联合3D俯卧位ABUS在乳腺致密女性中的性能和癌症检出率。我们的前瞻性观察性研究基于对1165名与风险因素无关的无症状乳腺致密女性的筛查。评估结果包括2017年6月至2019年2月期间检测到的癌症,所有检查均进行了双人阅片。乳腺钼靶检查发现了4例癌症,而乳腺钼靶检查联合俯卧位Sofia系统(3D ABUS)使检出率翻倍,共发现8例癌症。诊断率差异为每1000人中有3.4例。单纯乳腺钼靶检查每1000名女性的召回率为14.5,而乳腺钼靶检查联合3D俯卧位ABUS导致每1000名女性的召回率为26.6。我们还观察到每1000名接受筛查的女性中有额外12.1例召回。在乳腺密度高的女性中,将全场数字化乳腺钼靶(FFDM)与3D俯卧位ABUS相结合可显著提高乳腺癌检出率,包括小癌和浸润性癌,并且对召回率的影响可耐受。此外,3D俯卧位ABUS的性能结果与仰卧位3D ABUS系统的性能结果相当。