Department of Health and Preventive Medicine, School of Medicine, Showa University, Tokyo, Japan.
Pharmaceutical Education Center, Yokohama University of Pharmacy, Kanagawa, Japan.
J Occup Health. 2021 Jan;63(1):e12274. doi: 10.1002/1348-9585.12274.
In this study, we aimed to establish a method for quantifying bromide ions (Br ) in blood and urine using gas chromatograph-mass spectrometer (GC-MS) equipped with a headspace sampler, for biological monitoring of workers exposed to methyl bromide.
Samples were mixed with dimethyl sulfate, and Br ions were detected using GC-MS with a headspace sampler. The validity of the proposed method was evaluated based on most of the US FDA guidance. The values obtained were compared with reference values by analysis using Seronorm Trace Elements Whole Blood L-1 RUO.
The calibration curve showed good linearity in the Br concentration range of 0.1-20.0 mg/L, and the coefficient of determination R value was >.999. Intraday and interday accuracy values were 99.3%-103.1% and 97.4%-101.8%, respectively. The measured and reference values of Seronorm were concordant. Herein, eight urine and serum samples of workers were analyzed; the samples' Br concentrations were known. The correlation coefficients of urine and serum samples were 0.97 and 0.96, respectively, and results were consistent.
This study established a simple and rapid method for the determination of Br concentration in biological samples using GC-MS with a headspace sampler. Moreover, it can be used for biological monitoring of occupational exposure to methyl bromide and for the determination of Br concentration in a wide range of biological samples.
本研究旨在建立一种使用顶空进样气相色谱-质谱联用仪(GC-MS)定量测定血液和尿液中溴离子(Br-)的方法,用于监测接触甲基溴的作业人员。
样品与硫酸二甲酯混合,使用顶空进样 GC-MS 检测 Br-离子。根据美国 FDA 指南的大部分要求评估了所提议方法的有效性。通过使用 Seronorm Trace Elements Whole Blood L-1 RUO 进行分析,将获得的值与参考值进行比较。
校准曲线在 Br-浓度 0.1-20.0mg/L 范围内显示出良好的线性,决定系数 R 值>0.999。日内和日间准确度值分别为 99.3%-103.1%和 97.4%-101.8%。Seronorm 的实测值和参考值一致。在此,分析了 8 名工人的尿液和血清样本;已知样本的 Br-浓度。尿液和血清样本的相关系数分别为 0.97 和 0.96,结果一致。
本研究建立了一种使用顶空进样 GC-MS 快速测定生物样品中 Br-浓度的简单方法。此外,它可用于监测职业性接触甲基溴的生物暴露,并用于测定广泛范围内生物样品中的 Br-浓度。