An improved method for the simple determination of bromide ion in plasma is described. It was modified from the method by Kawai, Sugiyama et al. (1985). In the improved method, 200 microliters of plasma and 800 microliters of distilled water were placed in a reaction vial to which 100 microliters of dimethyl sulfate was added. The reaction vial was immediately sealed, placed in an incubator at 85 degrees C, and shaken for 10 min. At the end of the reaction, a gas-tight syringe was used to draw out the head space gas of 1 ml. The methyl bromide gas was then injected into a gas chromatograph and methyl bromide was determined with F.I.D. A good linear relationship was obtained between the peak area of methyl bromide and the concentration of bromide ion within the range of 0.5 to 500 ppm. Bromide ion in the range of 0.5 to 500 ppm in standard solution was added to the plasma samples. After 10 repeated measurements, the relative standard deviation was found to be in the range of 2.8-3.6% and recovery was over 96%. The analytical results of this method were compared with those obtained by spectrophotometry. The analytical results obtained by the two methods were in good agreement (r = 0.9669) in plasma samples of 10 methyl bromide workers. A study to determine bromide ion concentration in 39 methyl bromide workers was made and the results were compared with those observed in 100 workers (control group) not exposed to methyl bromide.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

本文描述了一种改进的简单测定血浆中溴离子的方法。该方法是对Kawai、Sugiyama等人(1985年)的方法进行改进而来。在改进方法中,将200微升血浆和800微升蒸馏水置于反应瓶中,向其中加入100微升硫酸二甲酯。反应瓶立即密封,置于85℃的培养箱中,振荡10分钟。反应结束后,用气密注射器抽出1毫升顶空气体。然后将溴甲烷气体注入气相色谱仪,用氢火焰离子化检测器(F.I.D.)测定溴甲烷。在0.5至500 ppm范围内,溴甲烷的峰面积与溴离子浓度之间呈现良好的线性关系。将0.5至500 ppm范围内标准溶液中的溴离子添加到血浆样品中。经过10次重复测量,相对标准偏差在2.8 - 3.6%范围内,回收率超过96%。将该方法的分析结果与分光光度法得到的结果进行比较。在10名接触溴甲烷工人的血浆样品中,两种方法得到的分析结果吻合良好(r = 0.9669)。对39名接触溴甲烷工人的溴离子浓度进行了测定,并将结果与100名未接触溴甲烷的工人(对照组)的观察结果进行了比较。(摘要截短至250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验