Suppr超能文献

通过用于透射电子显微镜的细胞培养物整装制备法对支原体污染进行阳性检测。

Positive detection of mycoplasma contamination by the whole-mount preparation of cell cultures for transmission electron microscopy.

作者信息

Maul G

出版信息

J Bacteriol. 1978 Mar;133(3):1452-6. doi: 10.1128/jb.133.3.1452-1456.1978.

Abstract

Low-level mycoplasma contamination of cell cultures is difficult to recognize with presently available techniques. This report describes the adaptation of the whole-mount technique, usually used for scanning microscopy, for transmission electron microscopy. The differentiation between microvilli and the equal-sized filamentous mycoplasma is based on the differential density obtained by the use of the method described. This method allows positive identification of mycoplasma and reduces the preparation time and the time necessary for scanning the preparation.

摘要

目前可用的技术难以识别细胞培养物中的低水平支原体污染。本报告描述了将通常用于扫描显微镜检查的整装技术应用于透射电子显微镜检查。微绒毛和大小相等的丝状支原体之间的区分基于使用所述方法获得的密度差异。该方法能够对支原体进行阳性鉴定,并减少了制备时间以及扫描制备物所需的时间。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9949/222184/3912bebdeb1e/jbacter00298-0415-a.jpg

相似文献

2
Beware of mycoplasmas.谨防支原体。
Trends Biotechnol. 1993 Apr;11(4):143-51. doi: 10.1016/0167-7799(93)90089-R.