Oral Surg Oral Med Oral Pathol. 1987 Jan;63(1):94-102. doi: 10.1016/0030-4220(87)90347-1.
Kodak's Ektaspeed (E) dental film is twice as fast as Ultraspeed (D) film and thereby significantly reduces radiation exposure to the patient. The film quality of the E film and D film was compared following processing with two manual and two automatic processing techniques. E-speed film processed manually or automatically produces diagnostically acceptable radiographs, with film densities within the recommended density limits commonly used in dentistry. High-contrast and low-contrast radiographs can be achieved by varying processing techniques.
柯达的超高速(E型)牙科胶片的感光度是超高速(D型)胶片的两倍,从而显著减少了患者所受的辐射量。在用两种手动和两种自动冲洗技术冲洗后,对E型胶片和D型胶片的质量进行了比较。手动或自动冲洗的E速胶片都能产生诊断上可接受的X光片,其胶片密度在牙科常用的推荐密度范围内。通过改变冲洗技术可以获得高对比度和低对比度的X光片。