Suppr超能文献

针对前交叉韧带(ACL)损伤及ACL重建术后患者的瑞典膝关节自我效能感量表18项版本的验证

Validation of an 18-item version of the Swedish Knee Self-Efficacy Scale for patients after ACL injury and ACL reconstruction.

作者信息

Beischer S, Hamrin Senorski E, Thomeé P, Thomeé R

机构信息

Unit of Physiotherapy, Department of Health and Rehabilitation, Institute of Neuroscience and Physiology, The Sahlgrenska Academy, University of Gothenburg, Box 455, SE-405 30, Gothenburg, Sweden.

Sportrehab Sports Medicine Clinic, Stampgatan 14, SE-411 01, Gothenburg, Sweden.

出版信息

J Exp Orthop. 2021 Oct 25;8(1):96. doi: 10.1186/s40634-021-00414-2.

Abstract

PURPOSE

To evaluate the measurement properties of a new version of the Swedish Knee Self-Efficacy Scale (K-SES) in samples of individuals with an anterior cruciate ligament (ACL) injury and after ACL reconstruction. A secondary aim was to translate the new version of K-SES into English in order to prepare for future complete cross-cultural adaptation.

METHODS

The reliability, structural validity, internal consistency and construct validity of the new, 18-item version of the K-SES (K-SES) were assessed according to the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist for evaluating methodological quality. The Swedish version of the K-SES was translated to English using recommended guidelines.

RESULTS

The test-retest reliability for the K-SES subscale present and the K-SES subscale future showed an Interclass Correlation Coefficient (ICC) = 0.92. In addition, the K-SES had a Cronbach's α ranging from 0.93 to 0.96 for the K-SES subscale present and from 0.81 to 0.91 for the K-SES subscale future. No floor and ceiling effects were identified for the subscale present or the subscale future of the K-SES. A factor analysis produced 2 factors of importance; K-SESpresent and K-SESfuture. Seven predefined hypotheses were confirmed.

CONCLUSION

The K-SES has acceptable reliability and validity to assess knee self-efficacy in patients up to 18 months after ACL injury and reconstruction.

LEVEL OF EVIDENCE

IV.

摘要

目的

评估新版瑞典膝关节自我效能量表(K - SES)在急性前交叉韧带(ACL)损伤个体样本以及ACL重建后的测量特性。次要目的是将新版K - SES翻译成英文,为未来完整的跨文化适应做准备。

方法

根据用于评估方法学质量的基于共识的健康测量工具选择标准(COSMIN)清单,对包含18个条目的新版K - SES(K - SES)的信度、结构效度、内部一致性和构想效度进行评估。使用推荐指南将瑞典版K - SES翻译成英文。

结果

K - SES当前子量表和K - SES未来子量表的重测信度显示组内相关系数(ICC)= 0.92。此外,K - SES当前子量表的克朗巴哈α系数在0.93至0.96之间,K - SES未来子量表的克朗巴哈α系数在0.81至0.91之间。未发现K - SES当前子量表或未来子量表存在地板效应和天花板效应。一项因素分析产生了两个重要因素;K - SES当前和K - SES未来。七个预定义假设得到证实。

结论

K - SES在评估ACL损伤和重建后长达18个月的患者膝关节自我效能方面具有可接受的信度和效度。

证据水平

IV级。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/34d5/8542523/ddc9a67637b1/40634_2021_414_Fig1_HTML.jpg