Suppr超能文献

多焦点人工晶状体植入术后与单焦点人工晶状体植入术后多焦点隐形眼镜佩戴期间的视觉性能及患者满意度比较:一项初步研究

Comparison of Visual Performance and Patient Satisfaction After Multifocal Intraocular Lens Implantation and During Multifocal Contact Lens Wear After Monofocal Intraocular Lens Implantation: A Pilot Study.

作者信息

Kamiya Kazutaka, Iijima Kei, Hiraoka Takahiro, Takada Keita, Mori Yosai, Miyata Kazunori

机构信息

Visual Physiology, School of Allied Health Sciences, Kitasato University, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa, 252-0373, Japan.

Department of Ophthalmology, School of Medicine, Kitasato University, Kanagawa, Japan.

出版信息

Ophthalmol Ther. 2021 Dec;10(4):1119-1128. doi: 10.1007/s40123-021-00414-6. Epub 2021 Oct 27.

Abstract

PURPOSE

To compare the visual performance and patient satisfaction in multifocal intraocular lens (IOL)-implanted eyes and multifocal contact lens (CL)-wearing eyes undergoing monofocal IOL implantation.

METHODS

We retrospectively assessed visual acuity at all distances (0.3, 0.5, 0.7, 1, and 5 m), contrast sensitivity function, patient satisfaction score, and the rate of spectacle independence in the multifocal IOL and multifocal CL groups.

RESULTS

Binocular visual acuity at 0.3, 0.5, 0.7, 1, and 5 m was 0.05 ± 0.11, - 0.02 ± 0.09, - 0.02 ± 0.09, - 0.02 ± 0.09, and - 0.04 ± 0.07, respectively, in the multifocal IOL group and 0.25 ± 0.13, 0.04 ± 0.10, 0.01 ± 0.09, - 0.01 ± 0.07, and 0.00 ± 0.08, respectively, in the multifocal CL group. We found significant differences in visual acuity at all distances. The area under the log contrast sensitivity function was 1.32 ± 0.14 and 1.33 ± 0.16 in the multifocal IOL and CL groups, respectively (p = 0.444). The patient satisfaction score for overall vision was 80.2 ± 20.6 and 82.9 ± 10.5 (p = 0.889), and the rate of spectacle independence was 23.4% and 41.7% in the multifocal IOL and CL groups, respectively (p = 0.277).

CONCLUSIONS

According to our experience, both multifocal IOLs and CLs provided good near-to-distance binocular vision and subsequent high patient satisfaction in daily activities with acceptable contrast sensitivity, suggesting their viability for presbyopic correction in elderly subjects.

摘要

目的

比较植入多焦点人工晶状体(IOL)的眼睛和佩戴多焦点隐形眼镜(CL)且接受单焦点IOL植入的眼睛的视觉性能和患者满意度。

方法

我们回顾性评估了多焦点IOL组和多焦点CL组在所有距离(0.3、0.5、0.7、1和5米)的视力、对比敏感度函数、患者满意度评分以及无需眼镜的比例。

结果

多焦点IOL组在0.3、0.5、0.7、1和5米处的双眼视力分别为0.05±0.11、-0.02±0.09、-0.02±0.09、-0.02±0.09和-0.04±0.07,多焦点CL组分别为0.25±0.13、0.04±0.10、0.01±0.09、-0.01±0.07和0.00±0.08。我们发现所有距离的视力均存在显著差异。多焦点IOL组和CL组的对数对比敏感度函数曲线下面积分别为1.32±0.14和1.33±0.16(p = 0.444)。总体视力的患者满意度评分分别为80.2±20.6和82.9±10.5(p = 0.889),多焦点IOL组和CL组无需眼镜的比例分别为23.4%和41.7%(p = 0.277)。

结论

根据我们的经验,多焦点IOL和CL均可提供良好的近远距离双眼视力,且在日常活动中具有较高的患者满意度以及可接受的对比敏感度,这表明它们在老年患者老花眼矫正方面具有可行性。