Abouelkheir Rasha T, Elawdy Mohamed Mohamed, Taha Diaa Eldin, El-Hamid Mohamed Abd, Osman Yasser, El-Diasty Tarek
Department of Radiology, Urology and Nephrology Center, Mansoura University, Mansoura, Egypt.
Urology Department, Sohar Hospital, Ministry of Health, Sohar, Oman.
Urol Ann. 2021 Oct-Dec;13(4):356-361. doi: 10.4103/UA.UA_32_20. Epub 2021 Sep 2.
Because the reports in the literature of radiologic investigations for upper tract urothelial cancer (UTUC) are limited by the number of patients, and included patients with different pathologies, we aimed to study the overall accuracy of computed tomography (CT) in the diagnosis of UTUC and their accuracy on predicting tumor location.
A retrospective review from 1990 to 2017 included patients who were treated for UTUC. Unenhanced CT scan was obtained first using Multi-Detector Computed Tomography (MDCT, Philips Medical Systems), then nonionic contrast medium, containing 350 mg iodine/ml was injected at 4 mL/s. Analysis was performed using SPSS.
Of 275 patients, complete data on CT was available on 270 (98%) patients. CT reported only two false positive and six false negative results and the overall accuracy was 96-97%. In comparison to the final pathological reports, CT/CTU detected 85% of the tumor location of in the renal pelvic and 50% of the calyceal tumors. In ureteric tumors, they detected distal (66/71= 93%) more than proximal ureteric tumors (60%).
In our cohort, CT/ CTU has a high overall accuracy (97%) in diagnosing UTUC, capability to well visualize tumors of distal ureter and renal pelvis, but could miss calyceal tumors. The matter to rely only on CT without ureteroscopic biopsy in the diagnosis of UTUC especially if radical surgery is planned needs further prospective studies.
由于上尿路尿路上皮癌(UTUC)放射学检查的文献报道受患者数量限制,且纳入了不同病理类型的患者,我们旨在研究计算机断层扫描(CT)诊断UTUC的总体准确性及其预测肿瘤位置的准确性。
对1990年至2017年接受UTUC治疗的患者进行回顾性研究。首先使用多排螺旋CT(MDCT,飞利浦医疗系统)进行平扫CT扫描,然后以4ml/s的速度注入含350mg碘/ml的非离子型造影剂。使用SPSS进行分析。
275例患者中,270例(98%)有完整的CT数据。CT仅报告了2例假阳性和6例假阴性结果,总体准确率为96%-97%。与最终病理报告相比,CT/CTU检测到肾盂肿瘤位置的占85%,肾盏肿瘤位置的占50%。在输尿管肿瘤中,检测到远端输尿管肿瘤的比例(66/71 = 93%)高于近端输尿管肿瘤(60%)。
在我们的队列中,CT/CTU诊断UTUC的总体准确率较高(97%),能够很好地显示远端输尿管和肾盂肿瘤,但可能漏诊肾盏肿瘤。在UTUC诊断中仅依靠CT而不进行输尿管镜活检,尤其是在计划进行根治性手术的情况下,这一问题需要进一步的前瞻性研究。