Suppr超能文献

两步同位素稀释电感耦合等离子体质谱法高精度测定人血清中的钾和硒

High-Accuracy Determination of Potassium and Selenium in Human Serum by Two-Step Isotope Dilution ICPMS.

作者信息

Yang Jian, Chi Lixia, Li Shengmin

机构信息

Institute of Disaster Prevention, Langfang 065201, China.

Key Laboratory of Building Collapse Mechanism and Disaster Prevention, China Earthquake Administration, Sanhe 065201, China.

出版信息

J Anal Methods Chem. 2021 Nov 6;2021:5533631. doi: 10.1155/2021/5533631. eCollection 2021.

Abstract

A high-accuracy measurement technique for determining potassium and selenium in human serum was developed by using two-step Isotope Dilution Inductively Coupled Plasma-Mass Spectrometry (ICPMS) in this research. A more accessible method of the quadrupole ICPMS was employed in this research to achieve an equally high accuracy which had been achieved by a much more expensive method, namely, high-resolution sector field ICPMS (SF-ICPMS), with a comparatively easy and simple operation. In addition, we have evaluated the uncertainty of this method. The results showed that the determination limits of potassium and selenium in serum were 0.8 mg/kg and 2.7 g/kg, respectively, and the precision for both measurements was lower than 0.2% and 0.7%. The measurement, when employed to measure potassium and selenium in standard materials NIST956D, NIST909C, and GBW09152, had caused a maximum deviation of less than 0.9%, within the stated uncertainty range of standard materials. The RELA international inter-laboratory comparisons of potassium in serum in 2018 conducted by our laboratory also yielded a satisfactory result.

摘要

本研究采用两步同位素稀释电感耦合等离子体质谱法(ICPMS)开发了一种测定人血清中钾和硒的高精度测量技术。本研究采用了一种更易操作的四极杆ICPMS方法,以实现与更昂贵的高分辨率扇形磁场ICPMS(SF-ICPMS)方法相同的高精度,且操作相对简便。此外,我们还评估了该方法的不确定度。结果表明,血清中钾和硒的测定限分别为0.8mg/kg和2.7μg/kg,两种测量的精密度均低于0.2%和0.7%。该测量方法用于测定标准物质NIST956D、NIST909C和GBW09152中的钾和硒时,在标准物质规定的不确定度范围内,最大偏差小于0.9%。本实验室在2018年进行的血清中钾的RELA国际实验室间比对也取得了满意的结果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验