《在不同步行条件下评估青少年步数时,Fitbit Ace 和 Moki 设备的有效性》。

Validity of the Fitbit Ace and Moki Devices for Assessing Steps During Different Walking Conditions in Young Adolescents.

出版信息

Pediatr Exerc Sci. 2022 Feb 1;34(1):1-5. doi: 10.1123/pes.2021-0026. Epub 2021 Nov 16.

Abstract

PURPOSE

Using wearable monitoring devices is increasingly ubiquitous, including among young people. However, there is limited evidence of the validity of devices which are aimed at children and adolescents. The purpose of this study was to evaluate the validity of Fitbit Ace and Moki monitors in healthy young adolescents.

METHODS

This cross-sectional study included 17 young adolescents (ages 11-13 y) ambulating between 3 different walking conditions (incidental [∼6 min], controlled, and treadmill [each 3 min], while wearing wrist-worn devices [Fitbit Ace, Moki] on each wrist [left and right, respectively]). Data from the devices were compared with observer counts (criterion). Bland-Altman plots and mean absolute percentage errors were computed.

RESULTS

Analyses identified that the Fitbit Ace showed higher levels of bias across conditions compared with the Moki device: (mean difference [SD]; Fitbit Ace: 30.0 [38.0], 3.0 [13.0], and 13.0 [23.0] steps and Moki: 1.0 [19.0], 4.0 [16.0], and 6.0 [14.0] steps, incidental, controlled, and treadmill, respectively). Mean absolute percentage errors ranged from 3.1% to 9.5% for the Fitbit Ace and 3.0% to 4.0% for the Moki device.

CONCLUSION

The Fitbit Ace and Moki devices might not provide acceptable validity under all walking conditions, but the Moki provides more accurate estimates of incidental walking and might therefore be a good choice for free-living research or school-based interventions.

摘要

目的

可穿戴监测设备的使用越来越普及,包括在年轻人中。然而,针对儿童和青少年的设备的有效性证据有限。本研究的目的是评估 Fitbit Ace 和 Moki 监测器在健康年轻青少年中的有效性。

方法

这项横断面研究包括 17 名年龄在 11-13 岁的青少年(在 3 种不同的步行条件下行走,包括偶然(约 6 分钟)、控制和跑步机(每种 3 分钟),同时在每个手腕上佩戴腕戴式设备(Fitbit Ace、Moki)[分别为左右手腕]。将设备数据与观察者计数(标准)进行比较。计算了 Bland-Altman 图和平均绝对百分比误差。

结果

分析表明,与 Moki 设备相比,Fitbit Ace 在所有条件下显示出更高的偏差水平:(平均差异[标准差];Fitbit Ace:30.0[38.0]、3.0[13.0]和 13.0[23.0]步,Moki:1.0[19.0]、4.0[16.0]和 6.0[14.0]步,分别为偶然、控制和跑步机)。Fitbit Ace 的平均绝对百分比误差范围为 3.1%至 9.5%,Moki 设备的平均绝对百分比误差范围为 3.0%至 4.0%。

结论

在所有步行条件下,Fitbit Ace 和 Moki 设备可能无法提供可接受的有效性,但 Moki 提供了更准确的偶然步行估计值,因此可能是自由生活研究或基于学校的干预的不错选择。