In this paper, a single-pixel mid-infrared (mid-IR) Hadamard transform spectrometer is developed. The spectrometer's design, fabrication and experimental results are discussed. The single-pixel mid-IR Hadamard transform spectrometer has dual cascaded encoding regions, 2875 nm to 3500 nm and 3500 nm to 4077 nm, to reduce the travel range required by the moving mask. The encoded wavelength band is determined by the bandpass filter used. A collection optics consisting of a reverse spectrometer is used to collect the encoded signal onto a single-pixel detector with a small sensing area. A 635 nm laser is used as a reference within the spectrometer to calibrate the recovered spectrum with accurate positioning. Our experiments demonstrate that mid-IR spectrums can be accurately recovered in the designed wavelength range. The proposed spectrometer, with dimensions of 200 mm × 200 mm × 84 mm and a weight of 1.8 kg, can be made portable and at low cost, suitable for IR spectroscopy in the field.

摘要

本文开发了一种单像素中红外(mid-IR)哈达玛变换光谱仪。讨论了该光谱仪的设计、制造及实验结果。单像素中红外哈达玛变换光谱仪有两个级联编码区域,分别为2875 nm至3500 nm和3500 nm至4077 nm,以减少移动掩膜所需的移动范围。编码波长带由所使用的带通滤波器确定。由反向光谱仪组成的收集光学器件用于将编码信号收集到具有小传感面积的单像素探测器上。光谱仪内使用635 nm激光作为参考,以通过精确定位校准恢复的光谱。我们的实验表明,在设计的波长范围内可以准确恢复中红外光谱。所提出的光谱仪尺寸为200 mm×200 mm×84 mm,重量为1.8 kg,可制成便携式且成本低廉,适用于现场红外光谱分析。