Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Department of Ultrasound, the Second Affiliated Hospital of Harbin Medical University, Harbin, China.
Clin Breast Cancer. 2022 Jun;22(4):e407-e416. doi: 10.1016/j.clbc.2021.10.009. Epub 2021 Oct 25.
To assess the performance of conventional ultrasound (US) combined with strain elastography (SE) in the Breast Imaging Reporting and Data System (BI-RADS) category 4 lesions on mammography.
Women with breast lesions identified as having mammography BI-RADS 4 lesions and underwent US examination were included in China. US features and US BI-RADS assessment were recorded in real-time and prospectively reported. The pathological result was referred to as the gold standard. The performance of US in the mammographic BI-RADS category 4 lesions was evaluated. Diagnostic performances of US BI-RADS, SE and combined both were compared.
A total of 751 women with 751 breast lesions classified as mammographic BI-RADS category 4 were included. For mammographic findings, 530 (70.6%) were true positive and 221 (29.4%) were false positive. Conventional US achieved higher positive predictive value (PPV) than mammography (78.5% vs. 70.6%, P=.001). The specificity increased from 34.4% to 47.1% (P< .001) without any loss in sensitivity and the PPV increased to 81.9% (P = .122) when conventional US was used in combination with SE. For conventional US combined with SE, it led to a correct diagnosis of no breast cancer in 104 of the 221 false-positive findings (47.1%) and achieved higher PPV than mammography regardless of patient age and lesion size.
Conventional US combined with SE is a helpful tool for the noninvasive examination of breast lesions classified as BI-RADS category 4 on mammography. It helped increase the PPV and had the potential to avoid unnecessary biopsies of BI-RADS category 4 lesions detected on mammography.
评估常规超声(US)联合应变弹性成像(SE)在乳腺影像报告和数据系统(BI-RADS)分类为 4 类的乳腺 X 线摄影病变中的表现。
在中国,将乳腺病变经乳腺 X 线摄影 BI-RADS 分类为 4 类并接受 US 检查的女性纳入研究。实时记录并前瞻性报告 US 特征和 US BI-RADS 评估。病理结果作为金标准。评估 US 在乳腺 X 线摄影 BI-RADS 4 类病变中的表现。比较 US BI-RADS、SE 及两者联合的诊断性能。
共纳入 751 例乳腺病变分类为乳腺 X 线摄影 BI-RADS 4 类的女性。对于乳腺 X 线摄影表现,530 例为真阳性(70.6%),221 例为假阳性(29.4%)。常规 US 的阳性预测值(PPV)高于乳腺 X 线摄影(78.5% vs. 70.6%,P=.001)。特异性从 34.4%增加到 47.1%(P<.001),而敏感性无任何损失,当常规 US 联合 SE 时,PPV 增加至 81.9%(P = .122)。对于常规 US 联合 SE,它导致 221 例假阳性发现中的 104 例(47.1%)被正确诊断为无乳腺癌,并提高了 PPV,无论患者年龄和病变大小如何,均优于乳腺 X 线摄影。
常规 US 联合 SE 是一种有助于对乳腺 X 线摄影 BI-RADS 分类为 4 类的乳腺病变进行非侵入性检查的工具。它有助于提高 PPV,并有可能避免对乳腺 X 线摄影发现的 BI-RADS 4 类病变进行不必要的活检。