Babina Ksenia, Polyakova Maria, Sokhova Inna, Doroshina Vladlena, Arakelyan Marianna, Zaytsev Alexandr, Novozhilova Nina
Department of Therapeutic Dentistry, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, Russia.
Institute of Linguistics and Intercultural Communication, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, Russia.
Nanomaterials (Basel). 2021 Nov 15;11(11):3072. doi: 10.3390/nano11113072.
We aimed to assess the effects of ultrasonic scaling and air-powder polishing on the roughness of enamel, three nanocomposites (Premise, Herculite Ultra, Harmonize), and composite/enamel and composite/cementum interfaces. Class V cavities were restored in 99 extracted third molars with one of the three nanocomposites and treated with ultrasonic scaler or air-powder polishing device (calcium carbonate or sodium bicarbonate powders). The roughness (Ra) of the investigated surfaces was measured with contact profilometer before and after treatment. The data were analyzed using repeated measures ANOVA. Specimens' Ra values before instrumentation were near the clinically acceptable 0.2 μm threshold. All techniques increased the roughness of the tested surfaces; however, the enamel was slightly affected. The mean Ra values after prophylaxis for composite, composite/cementum and composite/enamel surfaces were 0.32-0.55, 1.33-1.73, and 1.25-1.36, respectively. The extent of composite surface damage was material dependent. Premise surface was not altered by ultrasonic scaling significantly. Air-powder polishing with both powders produced a greater increase in surface roughness of composite resin and restorations margins than ultrasonic scaling. The Ra values after both types of air polishing for Herculite Ultra and Harmonize were approximately 1.5 and 2 times higher, respectively, than those after ultrasonic scaling ( < 0.05).
我们旨在评估超声洁治和喷粉抛光对牙釉质、三种纳米复合材料(Premise、Herculite Ultra、Harmonize)以及复合材料/牙釉质和复合材料/牙骨质界面粗糙度的影响。在99颗拔除的第三磨牙上制备V类洞,用三种纳米复合材料之一进行修复,并用超声洁治器或喷粉抛光装置(碳酸钙或碳酸氢钠粉末)进行处理。在处理前后,使用接触式轮廓仪测量研究表面的粗糙度(Ra)。数据采用重复测量方差分析进行分析。器械操作前样本的Ra值接近临床可接受的0.2μm阈值。所有技术均增加了测试表面的粗糙度;然而,牙釉质受影响较小。复合树脂、复合树脂/牙骨质和复合树脂/牙釉质表面预防性处理后的平均Ra值分别为0.32 - 0.55、1.33 - 1.73和1.25 - 1.36。复合树脂表面损伤程度取决于材料。Premise表面经超声洁治后无明显改变。与超声洁治相比,两种粉末的喷粉抛光使复合树脂和修复体边缘的表面粗糙度增加更大。Herculite Ultra和Harmonize两种喷粉抛光后的Ra值分别比超声洁治后高约1.5倍和2倍(P < 0.05)。