Ott D J, Chen Y M, Wu W C, Gelfand D W, Munitz H A
AJR Am J Roentgenol. 1986 Aug;147(2):261-5. doi: 10.2214/ajr.147.2.261.
Radiographic and endoscopic sensitivities were compared in 60 patients with lower esophageal mucosal ring. Barium esophagram detected 57 (95%) rings, all shown by the prone full-column technique. Double-contrast technique in 39 patients demonstrated only 18 (46%) rings. Endoscopy detected 35 (58%) of 60 rings. Endoscopic sensitivity depended on ring caliber with detection of 18 (82%) of 22 rings 13 mm or less in caliber, 14 (54%) of 26 14-19 mm rings, and three (25%) of 12 rings 20 mm or wider. Dysphagia was present in 13 of 25 patients with rings undetected by endoscopy. The caliber of the fiberoptic instruments used also affected endoscopic detection, with 47% of the rings being diagnosed with narrower endoscopes and 76% being diagnosed with larger instruments. Thus, the radiographic examination was more accurate in detecting lower esophageal mucosal ring and should be used initially in patients with dysphagia and suspected lower esophageal narrowing.
对60例患有食管下黏膜环的患者的影像学和内镜敏感性进行了比较。食管钡餐造影检测到57个(95%)环,均通过俯卧全柱技术显示。39例患者的双重对比技术仅显示18个(46%)环。内镜检查发现60个环中的35个(58%)。内镜敏感性取决于环的口径,口径为13毫米或更小的22个环中检测到18个(82%),14 - 19毫米的26个环中检测到14个(54%),20毫米或更宽的12个环中检测到3个(25%)。25例内镜未检测到环的患者中有13例存在吞咽困难。所用纤维光学器械的口径也影响内镜检测,使用较窄内镜诊断出47%的环,使用较大器械诊断出76%的环。因此,影像学检查在检测食管下黏膜环方面更准确,对于有吞咽困难和疑似食管下狭窄的患者应首先使用。