Suppr超能文献

小切口微透镜取出 ReLEX 矫正近视及近视散光术后 1 年的疗效。

One year outcomes after small incision lenticule extraction ReLEX in the correction of myopia and myopic astigmatism.

机构信息

Department of Ophthalmology, "Iuliu Hațieganu" University of Medicine and Pharmacy, Victor Babeș Str., no. 8, 400012, Cluj-Napoca, Romania.

Oculens Clinic, Calea Turzii, No. 134-136, 400501, Cluj-Napoca, Romania.

出版信息

BMC Ophthalmol. 2021 Dec 8;21(1):423. doi: 10.1186/s12886-021-02195-9.

Abstract

PURPOSE

To report the visual and refractive outcomes of small incision lenticule extraction ReLEX (SMILE) technique using VisuMax femtosecond laser in myopia and myopic astigmatism patients.

MATERIAL AND METHODS

A non-randomized clinical study has been conducted on patients with myopia and myopic astigmatism who underwent ReLEX SMILE technique, using the Zeiss VisuMax Laser system (Carl Zeiss Meditec AG, Jena, Germany) at Oculens Clinic, Cluj-Napoca, Romania. Patients older than 18 years, with ocular astigmatism up to -5 diopters (D), spherical equivalent up to -10.00 D, corrected distance visual acuity (CDVA) of 0.3 or better before the surgery, stable refraction for one year, and with a minimum calculated post operator residual stromal bed of 250μ were included in the study.

RESULTS

The study involved a total of 25 myopic eyes (median of sphere diopters equal with -4D) and 67 myopic astigmatic eyes (median of cylinder diopters equal with -1.5 D). The mean refractive spherical equivalent (MRSE) on patients with myopic eyes reduced from -4.25D (median) to -0.5D at one month follow-up, -0.25 D at 6 and 12 months. The mean refractive spherical equivalent (MRSE) on patients with astigmatic myopic eyes reduced from-6.25 D to -0.67 D at one month, -0.62 D at six and twelve months. The value of sphere decreased postoperatively on myopic eyes with a median of -0.25D at one, six and twelve months. The value of cylinder decreased postoperatively on myopic astigmatic eyes with a median of -0.50 D at one month, -0.25 D at six months and -0.50 D at 12 months. At 6 and 12 months, 20 (80.0%) of myopic eyes were maintained within ±0.5 D and 22 (88.0%) with ±1D. On both groups (myopic eyes and myopic astigmatic eyes), statistically significant differences were observed when the keratometric baseline values were compared to each follow-up (P-values < 0.0001), without any significant differences between follow-ups (P-values>0.15). At 1-month follow-up, uncorrected distance visual acuity (UDVA) was better than or equal to 0.5 in 88.0% of myopic eyes and 82.1% of myopic astigmatic eyes. UDVA remained stable in all cases of myopic eyes at six months and the percentage increased at 92.0% in myopic eyes. UDVA slightly increased at 6-months (85.1%) and remained at the same value at 12-months in myopic astigmatism eyes.

CONCLUSIONS

SMILE proved an effective and safe refractive corneal procedure and provided a predictable and stable correction of myopia and myopic astigmatism. SMILE technique demonstrated very good outcomes in terms of keratometric, cylinder, spherical measurements.

摘要

目的

报告使用 VisuMax 飞秒激光进行小切口透镜提取 ReLEX(SMILE)技术治疗近视和近视散光患者的视力和屈光结果。

材料和方法

在罗马尼亚克卢日-纳波卡的 Oculens 诊所,使用蔡司 VisuMax 激光系统(卡尔蔡司医疗技术公司,耶拿,德国)对近视和近视散光患者进行了一项非随机临床研究。纳入标准为年龄大于 18 岁、眼散光达 -5 屈光度(D)、等效球镜屈光度达 -10.00 D 以下、术前矫正远距视力(CDVA)为 0.3 或以上、屈光稳定一年、预计术后剩余基质床最小为 250μ 的患者。

结果

本研究共纳入 25 只近视眼(中位数等效球镜屈光度为 -4D)和 67 只近视散光眼(中位数柱镜屈光度为 -1.5 D)。术后 1 个月,近视眼患者的平均等效球镜(MRSE)从 -4.25D(中位数)降至 -0.5D,术后 6 个月和 12 个月分别降至 -0.25D。术后 1 个月,近视散光眼患者的平均等效球镜(MRSE)从 -6.25D 降至 -0.67D,术后 6 个月和 12 个月分别降至 -0.62D。术后 1 个月、6 个月和 12 个月,近视眼患者的球镜值中位数分别降低了 -0.25D。术后 1 个月、6 个月和 12 个月,近视散光眼患者的柱镜值中位数分别降低了 -0.50D、-0.25D 和 -0.50D。术后 6 个月和 12 个月,20 只(80.0%)近视眼的屈光度维持在±0.5D 以内,22 只(88.0%)的屈光度维持在±1D 以内。两组(近视眼和近视散光眼)的角膜曲率基线值在各随访时间点的比较均具有统计学差异(P 值均<0.0001),而随访时间点之间无统计学差异(P 值均>0.15)。术后 1 个月,88.0%的近视眼和 82.1%的近视散光眼的未矫正远距视力(UDVA)优于或等于 0.5。所有近视眼在术后 6 个月时的 UDVA 均保持稳定,且 12 个月时增加至 92.0%。术后 6 个月时,近视散光眼的 UDVA 略有增加(85.1%),12 个月时保持不变。

结论

SMILE 是一种有效的、安全的角膜屈光手术,可提供近视和近视散光的可预测、稳定的矫正效果。SMILE 技术在角膜曲率、柱镜、球镜测量方面显示出非常好的效果。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/cec6/8656009/beff36fa2f8c/12886_2021_2195_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验