Suppr超能文献

采用负重CT对膝关节间隙宽度进行定量分析的三维研究:与非负重CT及负重X线摄影的比较

Three-dimensional analysis for quantification of knee joint space width with weight-bearing CT: comparison with non-weight-bearing CT and weight-bearing radiography.

作者信息

Fritz B, Fritz J, Fucentese S F, Pfirrmann C W A, Sutter R

机构信息

Department of Radiology, Balgrist University Hospital, Zurich, Switzerland; Faculty of Medicine, University of Zurich, Zurich, Switzerland.

New York University Grossman School of Medicine, New York University, New York, USA.

出版信息

Osteoarthritis Cartilage. 2022 May;30(5):671-680. doi: 10.1016/j.joca.2021.11.019. Epub 2021 Dec 7.

Abstract

OBJECTIVE

To compare computer-based 3D-analysis for quantification of the femorotibial joint space width (JSW) using weight-bearing cone beam CT (WB-CT), non-weight-bearing multi-detector CT (NWB-CT), and weight-bearing conventional radiographs (WB-XR).

DESIGN

Twenty-six participants prospectively underwent NWB-CT, WB-CT, and WB-XR of the knee. For WB-CT and NWB-CT, the average and minimal JSW was quantified by 3D-analysis of the minimal distance of any point of the subchondral tibial bone surface and the femur. Associations with mechanical leg axes and osteoarthritis were evaluated. Minimal JSW of WB-CT was further compared to WB-XR. Two-tailed p-values of <0.05 were considered significant.

RESULTS

Significant differences existed of the average medial and lateral JSW between WB-CT and NWB-CT (medial: 4.7 vs 5.1 mm [P = 0.028], lateral: 6.3 vs 6.8 mm [P = 0.008]). The minimal JSW on WB-XR (medial:3.1 mm, lateral:5.8 mm) were significantly wider compared to WB-CT and NWB-CT (both medial:1.8 mm, lateral:2.9 mm, all p < 0.001), but not significantly different between WB-CT and NWB-CT (all p ≥ 0.869). Significant differences between WB-CT and NWB-CT existed in participants with varus knee alignment for the average and the minimal medial JSW (p = 0.004 and p = 0.011) and for participants with valgus alignment for the average lateral JSW (p = 0.013). On WB-CT, 25% of the femorotibial compartments showed bone-on-bone apposition, which was significantly higher when compared to NWB-CT (10%,P = 0.008) and WB-XR (8%,P = 0.012).

CONCLUSION

Combining WB-CT with 3D-based assessment allows detailed quantification of the femorotibial joint space and the effect of knee alignment on JSW. WB-CT demonstrates significantly more bone-on-bone appositions, which are underestimated or even undetectable on NWB-CT and WB-XR.

摘要

目的

比较使用负重锥形束CT(WB-CT)、非负重多层螺旋CT(NWB-CT)和负重传统X线片(WB-XR)对胫股关节间隙宽度(JSW)进行基于计算机的三维分析。

设计

26名参与者前瞻性地接受了膝关节的NWB-CT、WB-CT和WB-XR检查。对于WB-CT和NWB-CT,通过对胫骨软骨下骨表面与股骨任意点之间的最小距离进行三维分析来量化平均和最小JSW。评估其与机械腿轴和骨关节炎的相关性。将WB-CT的最小JSW与WB-XR进一步比较。双侧p值<0.05被认为具有统计学意义。

结果

WB-CT和NWB-CT之间平均内侧和外侧JSW存在显著差异(内侧:4.7对5.1mm[P = 0.028],外侧:6.3对6.8mm[P = 0.008])。与WB-CT和NWB-CT相比,WB-XR上的最小JSW(内侧:3.1mm,外侧:5.8mm)明显更宽(内侧均为:1.8mm,外侧:2.9mm,所有p<0.001),但WB-CT和NWB-CT之间无显著差异(所有p≥0.869)。在膝内翻参与者中,WB-CT和NWB-CT之间平均和最小内侧JSW存在显著差异(p = 0.004和p = 0.011),在膝外翻参与者中,平均外侧JSW存在显著差异(p = 0.013)。在WB-CT上,25%的胫股关节间隙显示骨对骨接触,与NWB-CT(10%,P = 0.008)和WB-XR(8%,P = 0.012)相比显著更高。

结论

将WB-CT与基于三维的评估相结合,可以详细量化胫股关节间隙以及膝关节对线对JSW的影响。WB-CT显示出明显更多的骨对骨接触,而在NWB-CT和WB-XR上这些接触被低估甚至无法检测到。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验