Tian Mi, Jian Weijun, Miao Huamao, Li Meng, Xia Fei, Zhou Xingtao
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, 19# Baoqing Road, Shanghai, 200031, People's Republic of China.
NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, 200031, People's Republic of China.
Ophthalmol Ther. 2022 Feb;11(1):355-363. doi: 10.1007/s40123-021-00436-0. Epub 2021 Dec 14.
This study investigated the long-term visual and optical quality changes after small incision lenticule extraction (SMILE) for the correction of moderate to high myopia.
Forty-one eyes of 41 patients with a mean spherical equivalent (SE) of - 6.74 ± 1.45 D undergoing SMILE were enrolled. Preoperative and 1-month, 3-month, 1-year and 5-year postoperative follow-up examinations were performed including visual acuity, manifest refraction, corneal aberrations and contrast sensitivity. An optical quality analysis system was used to measure objective scatter index (OSI), Strehl ratio (SR) and modulation transfer function cutoff frequency (MTF).
The safety and efficacy indices were 1.09 ± 0.12 and 1.03 ± 0.17, respectively, at the 5-year follow-up. No significant changes in SE from 1 month to 5 years postoperatively were found. The OSI significantly increased at 1 and 3 months postoperatively (p < 0.01 and p < 0.01) and declined at 1 and 5 years (p = 0.81 and p = 0.87). MTF and SR showed similar trends. Coma, spherical aberration and total higher-order aberration significantly increased after SMILE (p < 0.01) and remained stable from 1 month to 5 years after surgery (p > 0.05). Contrast sensitivity in the photopic and mesopic condition showed no significant changes during 5-year follow-up (p > 0.05).
The SMILE procedure is satisfactory in terms of optical quality for correcting moderate and high myopia in the long-term period.
ChiCTR-ONRC-13003114.
本研究调查了小切口透镜切除术(SMILE)矫正中高度近视后的长期视觉和光学质量变化。
纳入41例平均等效球镜度(SE)为-6.74±1.45D的患者的41只眼睛,接受SMILE手术。进行术前以及术后1个月、3个月、1年和5年的随访检查,包括视力、显验光、角膜像差和对比敏感度。使用光学质量分析系统测量客观散射指数(OSI)、斯特列尔比(SR)和调制传递函数截止频率(MTF)。
5年随访时,安全性和有效性指数分别为1.09±0.12和1.03±0.17。术后1个月至5年,SE未发现显著变化。术后1个月和3个月时OSI显著增加(p<0.01和p<0.01),1年和5年时下降(p=0.81和p=0.87)。MTF和SR呈现相似趋势。SMILE术后彗差、球差和总高阶像差显著增加(p<0.01),术后1个月至5年保持稳定(p>0.05)。在5年随访期间,明视觉和 mesopic 条件下的对比敏感度无显著变化(p>0.05)。
SMILE手术在长期矫正中高度近视的光学质量方面令人满意。