Suppr超能文献

一种量化角膜塑形术隐形眼镜佩戴后上皮和基质厚度变化的新方法。

A new approach for quantifying epithelial and stromal thickness changes after orthokeratology contact lens wear.

作者信息

Ran Ziying, Moore Joshua, Jiang Fan, Guo Hongmei, Eliasy Ashkan, Lopes Bernardo T, Bao FangJun, Jiang Jun, Abass Ahmed, Elsheikh Ahmed

机构信息

School of Engineering, University of Liverpool, Liverpool, UK.

Department of Mathematical Sciences, School of Physical Sciences, University of Liverpool, Liverpool, UK.

出版信息

R Soc Open Sci. 2021 Dec 22;8(12):211108. doi: 10.1098/rsos.211108. eCollection 2021 Dec.

Abstract

The aim of the study was to develop an automatic segmentation approach to optical coherence tomography (OCT) images and to investigate the changes in epithelial and stromal thickness profile and radius of curvature after the use of orthokeratology (Ortho-K) contact lenses. A total of 45 right eyes from 52 participants were monitored before, and after one month of, uninterrupted overnight Ortho-K lens wear. The tomography of their right eyes was obtained using optical OCT and rotating Scheimpflug imaging (OCULUS Pentacam). A custom-built MATLAB code for automatic segmentation of corneal OCT images was created and used to assess changes in epithelial thickness, stromal thickness, corneal and stromal profiles and radii of curvature before, and after one month of, uninterrupted overnight wear of Ortho-K lenses. In the central area (0-2 mm diameter), the epithelium thinned by 12.8 ± 6.0 µm (23.8% on average, < 0.01) after one month of Ortho-K lens wear. In the paracentral area (2-5 mm diameter), the epithelium thinned nasally and temporally (by 2.4 ± 5.9 µm, 4.5% on average, = 0.031). The stroma thickness increased in the central area (by 4.8 ± 16.1 µm, = 0.005). The radius of curvature of the central corneal anterior surface increased by 0.24 ± 0.26 mm (3.1%, < 0.01) along the horizontal meridian and by 0.34 ± 0.18 mm (4.2%, < 0.01) along the vertical meridian. There were no significant changes in the anterior and posterior stromal radius of curvature. This study introduced a new method to automatically detect the anterior corneal surface, the epithelial posterior surface and the posterior corneal surface in OCT scans. Overnight wear of Ortho-K lenses caused thinning of the central corneal epithelium. The anterior corneal surface became flattered while the anterior and posterior surfaces of the stroma did not undergo significant changes. The results are consistent with the changes reported in previous studies. The reduction in myopic refractive error caused by Ortho-K lens wear was mainly due to changes in corneal epithelium thickness profile.

摘要

本研究的目的是开发一种用于光学相干断层扫描(OCT)图像的自动分割方法,并研究使用角膜塑形术(Ortho-K)隐形眼镜后上皮和基质厚度分布以及曲率半径的变化。对52名参与者的45只右眼在连续夜间佩戴Ortho-K镜片前和佩戴一个月后进行了监测。使用光学OCT和旋转Scheimpflug成像(OCULUS Pentacam)获得其右眼的断层扫描图像。创建了一个用于自动分割角膜OCT图像的定制MATLAB代码,并用于评估连续夜间佩戴Ortho-K镜片前和佩戴一个月后上皮厚度、基质厚度、角膜和基质轮廓以及曲率半径的变化。在中央区域(直径0-2毫米),佩戴Ortho-K镜片一个月后,上皮变薄了12.8±6.0微米(平均变薄23.8%,<0.01)。在旁中央区域(直径2-5毫米),上皮在鼻侧和颞侧变薄(变薄2.4±5.9微米,平均变薄4.5%,=0.031)。中央区域的基质厚度增加(增加4.8±16.1微米,=0.005)。中央角膜前表面的曲率半径沿水平子午线增加了0.24±0.26毫米(增加3.1%,<0.01),沿垂直子午线增加了0.34±0.18毫米(增加4.2%,<0.01)。前后基质曲率半径没有显著变化。本研究引入了一种在OCT扫描中自动检测角膜前表面、上皮后表面和角膜后表面的新方法。夜间佩戴Ortho-K镜片导致中央角膜上皮变薄。角膜前表面变得更平坦,而基质的前后表面没有发生显著变化。结果与先前研究报告的变化一致。Ortho-K镜片佩戴引起的近视屈光不正降低主要是由于角膜上皮厚度分布的变化。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1223/8692962/d6751ae8b63c/rsos211108f01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验