Utz J A, Herfkens R J, Heinsimer J A, Bashore T, Califf R, Glover G, Pelc N, Shimakawa A
AJR Am J Roentgenol. 1987 May;148(5):839-43. doi: 10.2214/ajr.148.5.839.
Cine MR imaging provides tomographic images of the heart with both high spatial and high temporal resolution. As many as 32 images per cardiac cycle can be acquired with up to four separate anatomic slices and a total imaging time of 128 cardiac cycles. End-diastolic and end-systolic volumes were determined in 11 patients, and ejection fractions were calculated. The results correlated linearly with those from cardiac catheterization (correlation coefficient of .88). We conclude that cine MR imaging can be used to obtain quantitative information about the heart and has the potential to become a valuable noninvasive means of cardiac evaluation.
电影磁共振成像能够提供具有高空间分辨率和高时间分辨率的心脏断层图像。每个心动周期可获取多达32幅图像,最多有4个独立的解剖层面,总成像时间为128个心动周期。测定了11例患者的舒张末期和收缩末期容积,并计算了射血分数。结果与心导管检查结果呈线性相关(相关系数为0.88)。我们得出结论,电影磁共振成像可用于获取有关心脏的定量信息,并且有可能成为一种有价值的无创心脏评估手段。