Suppr超能文献

自由呼吸 2D 径向电影 MRI 结合呼吸自动校正运动校正(RAMCO)。

Free-breathing 2D radial cine MRI with respiratory auto-calibrated motion correction (RAMCO).

机构信息

Department MR R&D-Clinical Science, Best, The Netherlands.

Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.

出版信息

Magn Reson Med. 2023 Mar;89(3):977-989. doi: 10.1002/mrm.29499. Epub 2022 Nov 8.

Abstract

PURPOSE

To develop a free-breathing (FB) 2D radial balanced steady-state free precession cine cardiac MRI method with 100% respiratory gating efficiency using respiratory auto-calibrated motion correction (RAMCO) based on a motion-sensing camera.

METHODS

The signal from a respiratory motion-sensing camera was recorded during a FB retrospectively electrocardiogram triggered 2D radial balanced steady-state free precession acquisition using pseudo-tiny-golden-angle ordering. With RAMCO, for each acquisition the respiratory signal was retrospectively auto-calibrated by applying different linear translations, using the resulting in-plane image sharpness as a criterium. The auto-calibration determines the optimal magnitude of the linear translations for each of the in-plane directions to minimize motion blurring caused by bulk respiratory motion. Additionally, motion-weighted density compensation was applied during radial gridding to minimize through-plane and non-bulk motion blurring. Left ventricular functional parameters and sharpness scores of FB radial cine were compared with and without RAMCO, and additionally with conventional breath-hold Cartesian cine on 9 volunteers.

RESULTS

FB radial cine with RAMCO had similar sharpness scores as conventional breath-hold Cartesian cine and the left ventricular functional parameters agreed. For FB radial cine, RAMCO reduced respiratory motion artifacts with a statistically significant difference in sharpness scores (P < 0.05) compared to reconstructions without motion correction.

CONCLUSION

2D radial cine imaging with RAMCO allows evaluation of left ventricular functional parameters in FB with 100% respiratory efficiency. It eliminates the need for breath-holds, which is especially valuable for patients with no or impaired breath-holding capacity. Validation of the proposed method on patients is warranted.

摘要

目的

利用基于运动传感器的呼吸自动校准运动校正(RAMCO)技术,开发一种具有 100%呼吸门控效率的自由呼吸(FB)二维径向平衡稳态自由进动电影心脏 MRI 方法。

方法

在 FB 回顾性心电图触发的二维径向平衡稳态自由进动采集期间,使用伪微小黄金角度排序记录呼吸运动传感器的信号。使用 RAMCO,对于每次采集,通过应用不同的线性平移来回顾性地自动校准呼吸信号,使用所得的平面内图像锐度作为标准。自动校准确定了每个平面内方向的线性平移的最佳幅度,以最小化体部呼吸运动引起的运动模糊。此外,在径向网格化期间应用运动加权密度补偿,以最小化平面内和非体部运动模糊。在 9 名志愿者中,比较了具有和不具有 RAMCO 的 FB 径向电影以及额外的传统屏气笛卡尔电影的左心室功能参数和锐度评分。

结果

具有 RAMCO 的 FB 径向电影具有与传统屏气笛卡尔电影相似的锐度评分,并且左心室功能参数一致。对于 FB 径向电影,与没有运动校正的重建相比,RAMCO 减少了呼吸运动伪影,在锐度评分上有统计学显著差异(P < 0.05)。

结论

具有 RAMCO 的二维径向电影成像允许在 FB 中以 100%的呼吸效率评估左心室功能参数。它消除了屏气的需要,这对于没有或屏气能力受损的患者尤其有价值。需要对患者进行该方法的验证。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/70d1/10100319/8b771747f0a0/MRM-89-977-g004.jpg