Henningsson Markus, Carlhäll Carl-Johan, Ebbers Tino, Kihlberg Johan
Unit of Cardiovascular Sciences, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.
MAGMA. 2022 Oct;35(5):711-718. doi: 10.1007/s10334-021-00992-3. Epub 2021 Dec 27.
To evaluate systolic flow-sensitive alternating inversion recovery (FAIR) during rest and exercise stress using 2RR (two cardiac cycles) or 1RR intervals between inversion pulse and imaging.
1RR and 2RR FAIR was implemented on a 3T scanner. Ten healthy subjects were scanned during rest and stress. Stress was performed using an in-bore ergometer. Heart rate, mean myocardial blood flow (MBF) and temporal signal-to-noise ratio (TSNR) were compared using paired t tests.
Mean heart rate during stress was higher than rest for 1RR FAIR (85.8 ± 13.7 bpm vs 63.3 ± 11.1 bpm; p < 0.01) and 2RR FAIR (83.8 ± 14.2 bpm vs 63.1 ± 10.6 bpm; p < 0.01). Mean stress MBF was higher than rest for 1RR FAIR (2.97 ± 0.76 ml/g/min vs 1.43 ± 0.6 ml/g/min; p < 0.01) and 2RR FAIR (2.8 ± 0.96 ml/g/min vs 1.22 ± 0.59 ml/g/min; p < 0.01). Resting mean MBF was higher for 1RR FAIR than 2RR FAIR (p < 0.05), but not during stress. TSNR was lower for stress compared to rest for 1RR FAIR (4.52 ± 2.54 vs 10.12 ± 3.69; p < 0.01) and 2RR FAIR (7.36 ± 3.78 vs 12.41 ± 5.12; p < 0.01). 2RR FAIR TSNR was higher than 1RR FAIR for rest (p < 0.05) and stress (p < 0.001).
We have demonstrated feasibility of systolic FAIR in rest and exercise stress. 2RR delay systolic FAIR enables non-contrast perfusion assessment during stress with relatively high TSNR.
使用反转脉冲与成像之间的2RR(两个心动周期)或1RR间期,评估静息和运动应激状态下的收缩期血流敏感交替反转恢复(FAIR)。
在3T扫描仪上实施1RR和2RR FAIR。对10名健康受试者在静息和应激状态下进行扫描。使用内置测力计施加应激。采用配对t检验比较心率、平均心肌血流量(MBF)和时间信噪比(TSNR)。
对于1RR FAIR,应激期间的平均心率高于静息时(85.8±13.7次/分钟对63.3±11.1次/分钟;p<0.01),2RR FAIR也是如此(83.8±14.2次/分钟对63.1±10.6次/分钟;p<0.01)。对于1RR FAIR,应激时的平均MBF高于静息时(2.97±0.76毫升/克/分钟对1.43±0.6毫升/克/分钟;p<0.01),2RR FAIR也是如此(2.8±0.96毫升/克/分钟对1.22±0.59毫升/克/分钟;p<0.01)。静息时,1RR FAIR的平均MBF高于2RR FAIR(p<0.05),但在应激期间并非如此。对于1RR FAIR,应激时的TSNR低于静息时(4.52±2.54对10.12±3.69;p<0.01),2RR FAIR也是如此(7.36±3.78对12.41±5.12;p<0.01)。静息时(p<0.05)和应激时(p<0.001),2RR FAIR的TSNR高于1RR FAIR。
我们已经证明了收缩期FAIR在静息和运动应激状态下的可行性。2RR延迟收缩期FAIR能够在应激期间进行非对比灌注评估,且具有相对较高的TSNR。