Suppr超能文献

一种新型拳击监测系统的验证,用于检测和分析拳击手拳头上的压力中心运动。

Validation of a Novel Boxing Monitoring System to Detect and Analyse the Centre of Pressure Movement on the Boxer's Fist.

机构信息

Institute of Biomechanics and Orthopaedics, German Sport University Cologne, 50933 Cologne, Germany.

出版信息

Sensors (Basel). 2021 Dec 16;21(24):8394. doi: 10.3390/s21248394.

Abstract

The examination of force distribution and centre of pressure (CoP) displacement is a common method to analyse motion, load, and load distribution in biomechanical research. In contrast to gait analysis, the force progression in boxing punches is a new field of investigation. The centre of pressure displacement and distribution of forces on the surface of the fist during a boxing punch is of great interest and crucial to understanding the effect of the punch on the biological structures of the hand as well as the technical biomechanical aspects of the punching action. This paper presents a new method to display the CoP progression on the boxer's fist Therefore, this study presents the validation of the developed novel boxing monitoring system in terms of CoP displacement. In addition, the CoP progression of different punching techniques in boxing is analysed on the athlete's fist. The accuracy of the examination method of the CoP course was validated against the gold standard of a Kistler force plate. High correlations were detected between the developed sensor system and the force plate CoP with a Pearson correlation coefficient ranging from 0.93 to 0.97. The information obtained throughout the experimental study is of great importance in order to gain further knowledge into the technical execution of boxing punches as well as to provide a novel measuring method for determining CoP on the surface of the fist, to improve the understanding of the etiology of boxing-related hand injuries.

摘要

研究人员通过分析力的分布和压力中心(CoP)的位移来研究生物力学,这是一种常见的方法。与步态分析相比,拳击出拳时力的传递是一个新的研究领域。研究人员对拳击出拳时拳面上的 CoP 位移和力的分布非常感兴趣,因为这对于理解拳击对手部生物结构的影响以及出拳动作的技术生物力学方面至关重要。本文提出了一种新的方法来显示拳击手拳头上的 CoP 运动轨迹。因此,本研究从 CoP 位移的角度验证了所开发的新型拳击监测系统的有效性。此外,本研究还分析了拳击运动中不同拳击技术的 CoP 运动轨迹。研究人员将 CoP 轨迹的检测方法与测力板的金标准进行了对比,发现开发的传感器系统与测力板的 CoP 之间具有高度相关性,皮尔逊相关系数范围为 0.93 到 0.97。通过实验研究获得的信息对于进一步了解拳击出拳的技术执行情况以及提供一种新的测量方法来确定拳面上的 CoP 非常重要,这有助于提高对手部拳击伤病因的理解。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/bf30/8703349/9861ddd59139/sensors-21-08394-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验