Suppr超能文献

使用现代预制模板法经螺钉固定技术在尸体样本上进行第一和第二颈椎后路融合术

Posterior First and Second Cervical Vertebrae Fusion by Screw Fixation Technique using the Modern Pre-fabricated Template Method on Cadaver Samples.

作者信息

Athari M, Golbakhsh M R, Mirbolook A, Athari M, Ahmadi A, Komlakh K, Azarhomayoun A, Paydarniya P

机构信息

Department of Orthopaedics, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

Department of Orthopaedics, Tehran University of Medical Sciences, Tehran, Iran.

出版信息

Malays Orthop J. 2021 Nov;15(3):58-64. doi: 10.5704/MOJ.2111.009.

Abstract

INTRODUCTION

C1 lateral mass and C2 pedicular screws insertion are used for C1-C2 posterior fusion. Fluoroscopy Guided technique is routinely used for screw placement but it is associated with risk of injury to spinal cord and vertebral artery. 3D printing has developed rapidly in the fields of medicine. It is helpful in improving precise treatment and used for instrumentation in spine. We want to evaluate the accuracy of C1 lateral mass screws and C2 pedicle screws insertion by Pre-Fabricated Template made by three-dimensional (3D) printing.

MATERIALS AND METHODS

Five cervical samples were obtained from cadavers. Based on fine-cut CT scan 3D-images reconstructed and the path of the screws designed by special software. A template produced by 3D-printer from 3D images. After printing the templates, they were fixed on the relevant vertebra in the operation room and based on the template path, C1 lateral mass screw and C2 pedicular screws were inserted. Placement of the screws was evaluated using CT scans post-operatively.

RESULTS

A total of 14 screws were inserted by above-mentioned method. After evaluation with CT scans none of the screws were entered in the spinal canal. Two screws had vertebral artery canal perforation with less than 50% breach. Violation was judged as noncritical and would probably not have resulted in injury to vertebral artery.

CONCLUSIONS

The accuracy of C1 lateral mass screw and C2 pedicle screw insertion is acceptable with pre-fabricated template and can provide a useful aid for screw placement.

摘要

引言

C1侧块和C2椎弓根螺钉植入用于C1-C2后路融合。透视引导技术常用于螺钉置入,但存在脊髓和椎动脉损伤风险。3D打印在医学领域发展迅速。它有助于提高精准治疗并用于脊柱器械植入。我们想评估通过三维(3D)打印制作的预制模板进行C1侧块螺钉和C2椎弓根螺钉植入的准确性。

材料与方法

从尸体获取5个颈椎样本。基于薄层CT扫描重建3D图像,并通过特殊软件设计螺钉路径。由3D打印机根据3D图像制作模板。打印模板后,在手术室将其固定于相关椎体,并根据模板路径植入C1侧块螺钉和C2椎弓根螺钉。术后使用CT扫描评估螺钉置入情况。

结果

通过上述方法共植入14枚螺钉。经CT扫描评估,无一螺钉进入椎管。2枚螺钉有椎动脉管穿孔,穿孔小于50%。判定该违规情况不严重,可能不会导致椎动脉损伤。

结论

使用预制模板进行C1侧块螺钉和C2椎弓根螺钉植入的准确性可接受,可为螺钉置入提供有用辅助。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ff65/8667244/da6aff576137/moj-15-058-f001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验