Intrapartum suctioning of meconium: comparative efficacy of bulb syringe and De Lee catheter.

作者信息

Cohen-Addad N, Chatterjee M, Bautista A

机构信息

Department of Pediatrics, University of Medicine and Dentistry of New Jersey, Newark 07103.

出版信息

J Perinatol. 1987 Spring;7(2):111-3.

PMID:3505604
Abstract

Intrapartum suctioning of the newborn's pharynx with a De Lee catheter (DL) has reduced the incidence of meconium aspiration syndrome (MAS) in neonates born with meconium staining of the amniotic fluid. However, the bulb syringe (BLB) is used more often for this purpose because of greater technical convenience. In a prospective study, 60 offspring of such deliveries received intrapartum pharyngeal suctioning either by BLB (29 cases) or by DL (31 cases), according to random selection. The presence and amount of meconium in the trachea, incidence and severity of MAS, and mortality from the disease were similar between the two groups. This study suggests that the BLB is as effective as the DL for intrapartum removal of nasopharyngeal meconium in deliveries with meconium staining of the amniotic fluid. Since the BLB is easier to use, less expensive and probably safer, our results suggest that it may be the preferable method.

摘要

相似文献

1
Intrapartum suctioning of meconium: comparative efficacy of bulb syringe and De Lee catheter.
J Perinatol. 1987 Spring;7(2):111-3.
2
Delivery room management of meconium staining of the amniotic fluid and the development of meconium aspiration syndrome.羊水胎粪污染的产房管理与胎粪吸入综合征的发生
J Perinatol. 1988 Spring;8(2):127-31.
3
Delivery room management of infants born through thin meconium stained liquor.通过稀薄胎粪污染羊水出生的婴儿的产房管理
Indian Pediatr. 1994 Oct;31(10):1177-81.
4
Efficacy of bulb versus DeLee suction at deliveries complicated by meconium stained amniotic fluid.
Am J Perinatol. 1990 Jan;7(1):87-91. doi: 10.1055/s-2007-999454.
5
[Prevention of meconium aspiration].
Zentralbl Gynakol. 1988;110(17):1073-80.
6
[Intrapartum and postdelivery management of infants born to mothers with meconium-stained amniotic fluid].[羊水胎粪污染母亲所生婴儿的产时及产后管理]
Arch Pediatr. 2007 Nov;14(11):1389-93. doi: 10.1016/j.arcped.2007.09.001. Epub 2007 Oct 10.
7
Oropharyngeal and nasopharyngeal suctioning of meconium-stained neonates before delivery of their shoulders: multicentre, randomised controlled trial.在新生儿肩部娩出前对胎粪污染的新生儿进行口咽和鼻咽吸引:多中心随机对照试验。
Lancet. 2004;364(9434):597-602. doi: 10.1016/S0140-6736(04)16852-9.
8
The pros and cons of suctioning at the perineum (intrapartum) and post-delivery with and without meconium.会阴吸引术(分娩期)及产后有或没有胎粪情况下吸引术的利弊。
Semin Fetal Neonatal Med. 2008 Dec;13(6):375-82. doi: 10.1016/j.siny.2008.04.001. Epub 2008 May 13.
9
Failure to prevent meconium aspiration syndrome.
Obstet Gynecol. 1988 Mar;71(3 Pt 1):349-53.
10
Intrapartum and postdelivery management of infants born to mothers with meconium-stained amniotic fluid: evidence-based recommendations.羊水胎粪污染母亲所分娩婴儿的产时及产后管理:循证推荐意见
Clin Perinatol. 2006 Mar;33(1):29-42, v-vi. doi: 10.1016/j.clp.2005.11.014.

引用本文的文献

1
Appraisal of Meconium at Delivery: A look at intervention strategies.分娩时胎粪评估:干预策略探讨。
Can Fam Physician. 1992 Sep;38:2143-54.