Suppr超能文献

年轻人多焦点透气性角膜接触镜的视觉效果:一项初步研究。

Visual performance with multifocal corneal gas-permeable contact lenses in young adults: A pilot study.

机构信息

Optometry Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia; College of Optometry, Pacific University, Forest Grove, OR, United States.

College of Optometry, Pacific University, Forest Grove, OR, United States.

出版信息

J Optom. 2022 Oct-Dec;15(4):305-312. doi: 10.1016/j.optom.2022.01.001. Epub 2022 Feb 2.

Abstract

OBJECTIVES

To evaluate the performance of four experimental multifocal gas permeable contact lens (MFGPCL) designs and their impact on visual function in young adults.

METHODS

Seventeen young adults (age, 23.17 ± 4.48 years) enrolled in the study. Each participant was randomly assigned to wear two of four MFGPCL designs. They wore the first type of the assigned lens binocularly for one week and, after one week of washout period, wore another design on both eyes for another week. The four MFGPCL designs were as follows: design A (distance zone [DZ] 1.5 mm / add 3.0 D), B (DZ 1.5 mm / add 1.5 D), C (DZ 3.0 mm / add 3.0 D), and D (DZ 3.0 mm / add 1.5 D). Baseline visual acuity, contrast sensitivity function, and accommodation data were collected at baseline and repeated after one week of MFGPCL daily wear.

RESULTS

Distance and near visual acuities were not significant affected with the four MFGPCL designs. Contrast sensitivity was significantly lower in design A across all measured spatial frequencies (p < 0.05), with no significant impact from other designs on all frequencies. No significant effect was observed on accommodation measured at 33 cm (p > 0.05).

CONCLUSIONS

Three of the investigated MFGPCL designs preserve satisfactory visual performance. Lens design A incorporated with higher add and smaller center zone diameter had a stronger impact on the visual performance.

摘要

目的

评估四种实验性多焦点透气性角膜接触镜(MFGPCL)设计的性能及其对年轻人视觉功能的影响。

方法

17 名年轻人(年龄,23.17±4.48 岁)参与了这项研究。每位参与者被随机分配到佩戴四种 MFGPCL 设计中的两种。他们第一周双眼佩戴第一种设计的镜片,一周洗脱期后,又在双眼佩戴另一种设计的镜片一周。这四种 MFGPCL 设计如下:设计 A(远用区 [DZ] 1.5mm/附加 3.0D)、B(DZ 1.5mm/附加 1.5D)、C(DZ 3.0mm/附加 3.0D)和 D(DZ 3.0mm/附加 1.5D)。在基线和每周佩戴 MFGPCL 一 周后,收集基线和重复的视力、对比敏感度功能和调节数据。

结果

四种 MFGPCL 设计对远距和近距视力均无显著影响。在所有测量的空间频率上,设计 A 的对比敏感度显著降低(p<0.05),而其他设计对所有频率均无显著影响。在 33cm 处测量的调节没有观察到显著影响(p>0.05)。

结论

三种被研究的 MFGPCL 设计保持了令人满意的视觉性能。设计 A 中包含更高的附加度数和更小的中央区直径,对视觉性能的影响更强。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0b8c/9537242/bfe5c10cbb5b/gr1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验