Liappis N
Klin Padiatr. 1986 Jan-Feb;198(1):33-6. doi: 10.1055/s-2008-1026849.
The determination of methotrexate in serum was performed by the fluorescence polarization immunoassay (FPIA) and the enzyme immunoassay (EMIT). Both methods showed a good precision and accuracy. The investigation was carried out in 138 sera with a methotrexate concentration up to 1,400 mumol/l. The comparison of the two methods in 100 sera with a methotrexate concentration up to 5 mumol/l showed a good correlation (correlation coefficient r = 0.9798). Close correlation (correlation coefficient r = 0.9845) was also found in 38 sera with a methotrexate concentration between 5 and 1,400 mumol/l. Discussion of the FPIA and EMIT methods.
采用荧光偏振免疫分析法(FPIA)和酶免疫分析法(EMIT)测定血清中的甲氨蝶呤。两种方法均显示出良好的精密度和准确性。该研究在138份甲氨蝶呤浓度高达1400μmol/L的血清中进行。对100份甲氨蝶呤浓度高达5μmol/L的血清中两种方法的比较显示出良好的相关性(相关系数r = 0.9798)。在38份甲氨蝶呤浓度在5至1400μmol/L之间的血清中也发现了密切相关性(相关系数r = 0.9845)。FPIA和EMIT方法的讨论。