正电子发射断层扫描/计算机断层扫描(PET/CT)与骨髓检查在大B细胞淋巴瘤分期中的作用

The Role of Integrated Positron Emission Tomography/Computed Tomography (PET/CT) and Bone Marrow Examination in Staging Large B-Cell Lymphoma.

作者信息

Al-Sabbagh Ahmad, Ibrahim Feryal, Szabados Lajos, Soliman Dina S, Taha Ruba Y, Fernyhough Liam J

机构信息

Department of Laboratory Medicine and Pathology, National Center for Cancer Care and Research, Hamad Medical Corporation, Doha, Qatar.

Department of Medicine, Weill Cornell Medicine - Qatar, Doha, Qatar.

出版信息

Clin Med Insights Oncol. 2020 Oct 26;14:1179554920953091. doi: 10.1177/1179554920953091. eCollection 2020.

Abstract

INTRODUCTION

In the era of routine use of positron emission tomography/computed tomography (PET/CT) for staging, it is not yet clear whether PET/CT can replace bone marrow biopsy for the assessment of bone marrow involvement in large B-cell lymphoma.

OBJECTIVES

To compare the clinical utility of bone marrow biopsy and PET/CT scanning in the staging of large B-cell lymphoma.

METHODS

This was a retrospective analysis of all patients who presented to single center over a 4-year period with large B-cell lymphoma who had concurrent PET/CT and bone marrow biopsy performed in the assessment and staging of the lymphoma.

RESULTS

Out of 89 patients, 24 had bone marrow involvement either by PET/CT, by bone marrow biopsy, or by both. Bone marrow biopsy identified 12 patients (sensitivity 50%, specificity 100%, negative predictive value 84%), whereas PET/CT identified 23 patients (sensitivity 96%, specificity 100%, negative predictive value 98%). No patients were upstaged by the bone marrow biopsy result, and no patients had their treatment plan changed based on the bone marrow biopsy result.

CONCLUSION

The results show that PET-CT is more sensitive and has better negative predictive value than bone marrow biopsy. This suggests that PET-CT could replace bone marrow biopsy in detecting bone marrow involvement for staging of large B-cell lymphoma.

摘要

引言

在正电子发射断层扫描/计算机断层扫描(PET/CT)用于分期的常规应用时代,PET/CT是否能够替代骨髓活检来评估大B细胞淋巴瘤的骨髓受累情况尚不清楚。

目的

比较骨髓活检和PET/CT扫描在大B细胞淋巴瘤分期中的临床应用价值。

方法

这是一项对在4年期间就诊于单一中心的所有大B细胞淋巴瘤患者的回顾性分析,这些患者在淋巴瘤的评估和分期过程中同时进行了PET/CT和骨髓活检。

结果

89例患者中,24例通过PET/CT、骨髓活检或两者均显示有骨髓受累。骨髓活检确诊12例患者(敏感性50%,特异性100%,阴性预测值84%),而PET/CT确诊23例患者(敏感性96%,特异性l00%,阴性预测值98%)。没有患者因骨髓活检结果而被上调分期,也没有患者基于骨髓活检结果而改变治疗方案。

结论

结果表明,PET-CT比骨髓活检更敏感,且具有更好的阴性预测值。这表明PET-CT在检测大B细胞淋巴瘤分期的骨髓受累方面可以替代骨髓活检。