A simplified method for preparing blood serum and plasma for Zeeman electrothermal atomic absorption spectrometry is described and applied to the measurement of chromium in human serum and plasma. This enzymatic degradation with bacterial protease (EC 3.4.21.3) requires little laboratory apparatus, decreases the work and time of sample preparation, and obviates some potential sources of contamination. We used bovine reference serum (USDA No. 7292) to validate Cr concentration. There was less Cr in serum than in plasma, whether sodium heparin or sodium citrate was used as anticoagulant. For six human subjects, Cr in serum averaged 0.15 (SD 0.02) micrograms/L, 0.26 (SD 0.03) micrograms/L in heparinized plasma, and 0.28 (SD 0.02) micrograms/L in citrated plasma. We postulate that the Cr concentration is lower in serum because some of the Cr binds to proteins complexed with the clot in the coagulation process.

摘要

本文描述了一种用于塞曼电热原子吸收光谱法的血清和血浆制备简化方法,并将其应用于人体血清和血浆中铬的测定。这种用细菌蛋白酶(EC 3.4.21.3)进行的酶促降解所需的实验室仪器很少,减少了样品制备的工作量和时间,并且消除了一些潜在的污染源。我们使用牛参考血清(美国农业部第7292号)来验证铬浓度。无论使用肝素钠还是柠檬酸钠作为抗凝剂,血清中的铬含量均低于血浆。对于六名受试者,血清中铬的平均含量为0.15(标准差0.02)微克/升,肝素化血浆中为0.26(标准差0.03)微克/升,柠檬酸盐血浆中为0.28(标准差0.02)微克/升。我们推测血清中铬浓度较低是因为在凝血过程中一些铬与与凝块结合的蛋白质结合。