Suppr超能文献

双功超声扫描在评估下肢深静脉瓣膜功能不全中的应用

Duplex scanning in the assessment of deep venous incompetence.

作者信息

Szendro G, Nicolaides A N, Zukowski A J, Christopoulos D, Malouf G M, Christodoulou C, Myers K

出版信息

J Vasc Surg. 1986 Sep;4(3):237-42.

PMID:3528531
Abstract

A noninvasive method to evaluate deep venous incompetence by duplex scanning is presented. For this test, it was decided to have the patient standing so as to make the test less dependent on the need for patient cooperation and to allow gravity to produce reflux. Results were validated against ambulatory venous pressure measurements. The method described had a sensitivity of 84% and specificity of 88%. Duplex scanning is a useful screening test for detecting the presence and site of incompetence in patients with deep venous disease.

摘要

介绍了一种通过双功扫描评估深静脉功能不全的非侵入性方法。对于该测试,决定让患者站立,以使测试减少对患者合作的依赖,并让重力产生反流。结果与动态静脉压力测量结果进行了验证。所描述的方法灵敏度为84%,特异性为88%。双功扫描是检测深静脉疾病患者功能不全的存在和部位的一种有用的筛查测试。