BACKGROUND

Compared with traditional computed tomography (CT), dual-layer spectral detector CT (SDCT) shows significant improvement in imaging soft tissues of the digestive tract. This work aimed to explore the application of SDCT to evaluate the expression of the molecular marker Ki-67 in colorectal cancer.

METHODS

We retrospectively analyzed the imaging data of the SDCT (IQon Spectral CT; Philips Healthcare) of 45 patients with colorectal cancer in our centre. We used Spearman's test for the imaging parameters (reconstruction of 40, 70, and 100 keV virtual monoenergetic images [VMIs] and the slope of the Hounsfield unit attenuation plot [VMI Slope] based on venous phase CT images, the arterial phase iodine concentration [AP-IC] and venous phase iodine concentration [VP-IC], and the effective atomic number [Z effect]) and correlation analysis for the Ki-67 index. Multivariate logistic regression was used to eliminate confounding factors. We evaluated the expression level of Ki-67 and drew the receiver operating characteristic curve.

RESULTS

The 40-keV VMI, VMI Slope, and AP-IC were found to better reflect the Ki-67 index in patients with colorectal cancer with statistical significance. The 40-keV VMI (r = -0.612, p < 0.001) and VMI Slope (r = -0.523, p < 0.001) were negatively correlated with the Ki-67 index, and AP-IC (r = 0.378, p = 0.010) was positively correlated with the Ki-67 index. The other indexes (p > 0.05) were not statistically significant. The SDCT parameters demonstrated good performance, with area under curves of 0.785 for 40-keV VMI and 0.752 for AP-IC.

CONCLUSION

The SDCT parameters 40-keV VMI and AP-IC can be used for preliminary evaluation of the Ki-67 index in colorectal cancer.

摘要

背景

与传统的计算机断层扫描(CT)相比,双层能谱探测器 CT(SDCT)在消化道软组织成像方面有显著的改善。本研究旨在探讨 SDCT 用于评估结直肠癌中分子标志物 Ki-67 表达的应用。

方法

我们回顾性分析了本中心 45 例结直肠癌患者的 SDCT(IQon Spectral CT;Philips Healthcare)的影像学数据。我们使用 Spearman 检验对影像学参数(基于静脉期 CT 图像的 40keV、70keV 和 100keV 虚拟单能量图像(VMI)和单位衰减斜率[VMI Slope]、动脉期碘浓度[AP-IC]和静脉期碘浓度[VP-IC],以及有效原子序数[Z 值])和 Ki-67 指数进行了相关性分析。采用多元逻辑回归消除混杂因素。我们评估了 Ki-67 的表达水平并绘制了受试者工作特征曲线。

结果

40keV VMI、VMI Slope 和 AP-IC 与结直肠癌患者的 Ki-67 指数有更好的相关性。40keV VMI(r=-0.612,p<0.001)和 VMI Slope(r=-0.523,p<0.001)与 Ki-67 指数呈负相关,而 AP-IC(r=0.378,p=0.010)与 Ki-67 指数呈正相关。其他指标(p>0.05)无统计学意义。SDCT 各项参数均具有较好的性能,40keV VMI 的曲线下面积为 0.785,AP-IC 的曲线下面积为 0.752。

结论

SDCT 参数 40keV VMI 和 AP-IC 可用于初步评估结直肠癌中 Ki-67 指数。