BACKGROUND

Nerve wrapping has been advocated to minimize scarring and adhesion following neurorrhaphy or neurolysis. A wrap should provide an enclosure that is snug enough to protect and support the affected nerve without strangulating the nerve. The degree to which resorbable wraps should be ": tightened" around the nerve is largely subjective with scant literature on the subject. The purpose of this study was to evaluate the effects of tightly fitting resorbable nerve wraps around intact rat sciatic nerves.

METHODS

Twenty-four Sprague-Dawley rats underwent exposure and circumferential measurement of the right sciatic nerve. Porcine-derived extracellular matrix (ECM) wraps were trimmed and sutured to enclose the nerve with a tight (same as that of the nerve,   8) or loose (2.5x that of the nerve,   8) circumference. Sham-surgery control animals ( = 8) had no wrap treatment. Functional outcome was recorded biweekly by sciatic functional index (SFI) with walking track analysis and electrical stimulation. Animals were sacrificed at 12 weeks for histologic analyses.

RESULTS

No withdrawal response could be evoked in the tight-wrap group until week 9, while significant improvement in SFI first occurred between weeks 5 and 7. By week 12, the tight-wrap group required 60% more current compared with baseline stimulation to produce a withdrawal response. They recovered 81% of SFI baseline values but also demonstrated significantly greater intraneural collagen content ( < 0.001) and lower axon density ( < 0.05) than in the loose-wrap and sham groups. The loose-wrap group had comparable functional and histologic outcomes to the sham control group.

CONCLUSION

Resorbable ECM nerve wraps applied tightly around intact rat sciatic nerves caused significant functional impairment and histological changes characteristic of acute nerve compression. Significant but incomplete functional recovery was achieved by the tight-wrap group after 12 weeks, but such recovery may not apply in humans.

摘要

背景

神经包裹术被提倡用于减少神经缝合或神经松解术后的瘢痕形成和粘连。包裹物应提供一个足够贴合的封闭环境,以保护和支持受影响的神经,同时又不会压迫神经。可吸收包裹物围绕神经的“收紧”程度在很大程度上是主观的,关于这一主题的文献很少。本研究的目的是评估紧密贴合的可吸收神经包裹物对完整大鼠坐骨神经的影响。

方法

24只Sprague-Dawley大鼠接受右侧坐骨神经的暴露和周径测量。将猪源细胞外基质(ECM)包裹物修剪并缝合,以紧密(与神经周径相同,8)或宽松(神经周径的2.5倍,8)的周径围绕神经进行包裹。假手术对照组动物(n = 8)不进行包裹处理。通过坐骨神经功能指数(SFI)结合行走轨迹分析和电刺激,每两周记录一次功能结果。12周时处死动物进行组织学分析。

结果

紧密包裹组直到第9周才出现退缩反应,而SFI的显著改善首先出现在第5至7周之间。到第12周时,紧密包裹组与基线刺激相比,产生退缩反应所需的电流增加了60%。它们恢复了SFI基线值的81%,但与宽松包裹组和假手术组相比,神经内胶原含量显著更高(P < 0.001),轴突密度更低(P < 0.05)。宽松包裹组的功能和组织学结果与假手术对照组相当。

结论

紧密围绕完整大鼠坐骨神经应用可吸收ECM神经包裹物会导致明显的功能损害和急性神经压迫特征性的组织学变化。紧密包裹组在12周后实现了显著但不完全的功能恢复,但这种恢复可能不适用于人类。