Hogan J S, Cornetta A, Pankey J W
Am J Vet Res. 1986 Sep;47(9):2017-9.
A comparison was made between conventional tube coagulase, macrocupsular coagulase, latex agglutination, and miniaturized biochemical test systems for identification of Staphylococcus aureus of bovine origin. A total of 303 gram-positive, catalase-positive cocci of bovine origin were tested. Agreement between each pair of 4-hour tube coagulase, macrocupsular coagulase, latex agglutination, and miniaturized biochemical test results within isolates was greater than 95.0. Seventeen (5.6%) isolates were test negative for 4-hour tube coagulase, but test positive for 24-hour tube coagulase. Thirteen (76.5%) of these isolates were identified as S hyicus, 3 were S aureus, and 1 was not identified.
对传统试管凝固酶、大杯凝固酶、乳胶凝集试验和小型生化检测系统进行了比较,以鉴定牛源金黄色葡萄球菌。共检测了303株牛源革兰氏阳性、过氧化氢酶阳性球菌。各分离株的4小时试管凝固酶、大杯凝固酶、乳胶凝集试验和小型生化检测结果之间的一致性大于95.0%。17株(5.6%)分离株4小时试管凝固酶检测为阴性,但24小时试管凝固酶检测为阳性。其中13株(76.5%)分离株鉴定为猪葡萄球菌,3株为金黄色葡萄球菌,1株未鉴定。