Suppr超能文献

BIOMONITOR III 可注射式心脏监测仪:一种新型可注射式心脏监测仪的临床经验

The BIOMONITOR III Injectable Cardiac Monitor: Clinical Experience with a Novel Injectable Cardiac Monitor.

作者信息

Reinsch Nico, Füting Anna, Höwel Dennis, Neven Kars

机构信息

Department of Electrophysiology, Alfried Krupp Krankenhaus, 45131 Essen, Germany.

Department of Medicine, Witten/Herdecke University, 58448 Witten, Germany.

出版信息

J Clin Med. 2022 Mar 16;11(6):1634. doi: 10.3390/jcm11061634.

Abstract

BACKGROUND

Injectable cardiac monitors (ICMs) are leadless subcutaneous devices for long-term monitoring of arrhythmias. The BIOTRONIK BIOMONITOR III is a novel ICM with a miniaturized profile, long sensing vector, and simplified implantation technique.

METHODS

R-wave amplitude was recorded immediately after implantation, the day after implantation, and after 3 months. Follow-up was scheduled after 3 months or after an event. All data from the ICM were retrieved. The anatomical position of the ICM was determined post-implantation and after 3 months. A patient questionnaire was conducted after 3 months.

RESULTS

In 36 patients (mean age 67 ± 13 years; 40% male) an ICM was inserted. Six patients were not included in the final analysis. The median time from skin cut to wound closure was 6 [IQR 5-7] minutes. Mean R-wave amplitude increased over time (0.73 ± 32 mV vs. 0.78 ± 0.38 mV vs. 0.81 ± 0.39 mV; = ns). Three months after implantation, the ICM was in an anatomically stable position. In 14 (47%) patients, true episodes were detected. False arrhythmia alerts were detected in 13 (43%) patients. The total number of false detections was low, and the patient satisfaction rate was high.

CONCLUSION

Implantation of the novel BIOMONITOR III is fast and uncomplicated; its sensing characteristics are excellent and improve over time, and patient satisfaction is high.

摘要

背景

可植入式心脏监测器(ICM)是用于长期监测心律失常的无导线皮下装置。百多力BIOMONITOR III是一种新型ICM,具有小型化外形、长传感向量和简化的植入技术。

方法

在植入后即刻、植入后一天和3个月后记录R波振幅。计划在3个月后或事件发生后进行随访。检索来自ICM的所有数据。在植入后和3个月后确定ICM的解剖位置。3个月后进行患者问卷调查。

结果

36例患者(平均年龄67±13岁;40%为男性)植入了ICM。6例患者未纳入最终分析。从皮肤切开到伤口闭合的中位时间为6[四分位间距5 - 7]分钟。平均R波振幅随时间增加(0.73±0.32 mV对0.78±0.38 mV对0.81±0.39 mV;P =无显著性差异)。植入3个月后,ICM处于解剖学稳定位置。14例(47%)患者检测到真实发作。13例(43%)患者检测到假心律失常警报。假检测总数较低,患者满意率较高。

结论

新型BIOMONITOR III的植入快速且简单;其传感特性优异且随时间改善,患者满意度高。