在前交叉韧带重建术后 1 年内,使用腘绳肌腱自体移植物进行的 NordBord 离心测试中可发现持续的膝关节屈肌力量缺陷,但在“金标准”等速向心测试中则无法发现。

Persistent knee flexor strength deficits identified through the NordBord eccentric test not seen with "gold standard" isokinetic concentric testing during the first year after anterior cruciate ligament reconstruction with a hamstring tendon autograft.

机构信息

Sportrehab Sports Medicine Clinic, Stampgatan 14, SE-411 01, Gothenburg, Sweden; Unit of Physiotherapy, Department of Health and Rehabilitation, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg, Box 455, SE-405 30, Gothenburg, Sweden; Sahlgrenska Sports Medicine Center, Gothenburg, Sweden.

IFK-Kliniken Rehab, Sports Medicine Clinic, Topelsgatan 7, SE-416 55, Gothenburg, Sweden.

出版信息

Phys Ther Sport. 2022 May;55:119-124. doi: 10.1016/j.ptsp.2022.03.004. Epub 2022 Mar 15.

Abstract

OBJECTIVE

To investigate the recovery of knee flexor muscle strength evaluated with a Nordic hamstring eccentric test (NordBord) compared with an isokinetic concentric test (Biodex) during the first year after anterior cruciate ligament (ACL) reconstruction using a hamstring tendon autograft.

DESIGN

Prospective observational registry study; level of evidence, 3.

SETTING

Primary care.

PARTICIPANTS

Cross-sectional data of 127 patients (45% women, mean age 24.9 ± 8.1 years) were extracted from a rehabilitation outcome registry at 10 weeks and 4, 8 and 12 months after ACL reconstruction with hamstring tendon autograft.

MAIN OUTCOME MEASURES

All patients performed a concentric Biodex test, and an eccentric NordBord test on the same occasion or within seven days of the concentric test. The primary outcome was the limb symmetry index between the respective tests.

RESULTS

A greater knee flexor symmetry deficit was observed with the eccentric test compared with the concentric test at all follow-ups with clinically relevant differences at 4 (11.8% ± 12.7% [CI 7.8-15.8%]) and 8 months (13.4 ± 11.9 [CI 9.7-17.2%].

CONCLUSION

The eccentric NordBord test was able to identify clinically relevant deficits in knee flexor strength symmetry that were not identified by gold standard isokinetic concentric testing during the first year among patients treated with an ACL reconstruction using a hamstring tendon autograft.

摘要

目的

使用自体腘绳肌腱重建前交叉韧带(ACL)后,在第一年,通过北欧腘绳肌离心测试(NordBord)评估膝关节屈肌肌力的恢复情况,与等速向心测试(Biodex)进行比较。

设计

前瞻性观察性登记研究;证据水平,3 级。

地点

初级保健。

参与者

从一个康复结果登记处提取了 127 名患者(45%为女性,平均年龄 24.9±8.1 岁)的横断面数据,这些患者在 ACL 重建后 10 周、4、8 和 12 个月时分别接受了腘绳肌自体肌腱重建。

主要观察指标

所有患者均进行了等速 Biodex 测试和同一时间或在向心测试后 7 天内进行的偏心 NordBord 测试。主要结果是各自测试之间的肢体对称性指数。

结果

与向心测试相比,在所有随访中,偏心测试观察到更大的膝关节屈肌对称性缺陷,在 4 个月(11.8%±12.7%[CI 7.8-15.8%])和 8 个月(13.4%±11.9%[CI 9.7-17.2%])时具有临床相关差异。

结论

在使用自体腘绳肌腱重建 ACL 的患者中,在第一年中,偏心 NordBord 测试能够识别出膝关节屈肌力量对称性的临床相关缺陷,而黄金标准等速向心测试无法识别。