与圆锥角膜进展相关的活体生物力学变化。

In Vivo Biomechanical Changes Associated With Keratoconus Progression.

机构信息

Department of Cornea and Refractive Surgery, Sankara Nethralaya, Chennai, India.

School of Engineering, University of Liverpool, Liverpool, UK.

出版信息

Curr Eye Res. 2022 Jul;47(7):982-986. doi: 10.1080/02713683.2022.2058020. Epub 2022 Apr 21.

Abstract

PURPOSE

To assess the biomechanical deterioration arising from keratoconus progression .

METHODS

The preoperative examinations of 32 progressive KC cases that were submitted to corneal cross-linking were evaluated. The examinations included the corneal tomography using the Pentacam HR and biomechanical parameters assessed by the Corvis ST (Oculus, Wetzlar, Germany). The results were recorded at two time points, the latter of which was at the last visit before the CXL procedure. Keratoconus progression was characterised by a significant change in the ABCD system.

RESULTS

At the last follow-up visit (41.4 ± 40.9 months) all morphological parameters of the ABCD grading system showed significant deterioration ( < 0.001). The comparative analyses revealed a significant reduction in corneal stiffness expressed by a significant reduction in the stress-strain index (SSI: -0.10 ± 0.06,  < 0.001), the Stiffness parameter A1 (SP-A1: -6.1 ± 12.0 mmHg/mm,  = 0.011), by a significant increase in the integrated Inverse Radius (IIR: 0.95 ± 1.04 mm-1,  < 0.001) and in the deflection amplitude (DA) ratio (0.23 ± 0.58,  = 0.034). A barely significant increase in the DA also pointed towards corneal stiffness reduction. (0.04 ± 0.13 mm,  = 0.056). The SSI and the IIR were the indices with the smallest overlaps between the two examinations.

CONCLUSIONS

It has been demonstrated that corneal biomechanical deterioration occurs with keratoconus progression. The larger changes observed in the SSI and the IIR when compared to the remaining biomechanical parameters suggests that these parameters could be suitable to assess the corneal stiffness reduction in keratoconus natural progression.

摘要

目的

评估圆锥角膜进展引起的生物力学恶化。

方法

对 32 例接受角膜交联术的进展性 KC 病例的术前检查进行评估。检查包括使用 Pentacam HR 的角膜断层扫描和 Corvis ST(德国 Oculus,Wetzlar)评估的生物力学参数。结果记录在两个时间点,后者是在交联前的最后一次就诊时。圆锥角膜进展的特征是 ABCD 系统的显著变化。

结果

在最后一次随访(41.4±40.9 个月)时,ABCD 分级系统的所有形态参数均显示出显著恶化( <0.001)。比较分析显示,角膜硬度明显降低,表现为应力-应变指数(SSI)显著降低(-0.10±0.06, <0.001),硬度参数 A1(SP-A1:-6.1±12.0mmHg/mm, =0.011)显著降低,整合反半径(IIR)显著增加(0.95±1.04mm-1, <0.001),挠度幅度(DA)比显著增加(0.23±0.58, =0.034)。DA 也略有增加,这也表明角膜硬度降低。(0.04±0.13mm, =0.056)。SSI 和 IIR 是两次检查中重叠最小的指标。

结论

研究表明,圆锥角膜进展时会发生角膜生物力学恶化。与其余生物力学参数相比,SSI 和 IIR 观察到的变化更大,表明这些参数可能适合评估圆锥角膜自然进展中的角膜硬度降低。