Suppr超能文献

高频交流电经皮电刺激对健康志愿者感觉运动系统的影响:一项双盲随机对照研究。

Effect of Percutaneous Electric Stimulation with High-Frequency Alternating Currents on the Sensory-Motor System of Healthy Volunteers: A Double-Blind Randomized Controlled Study.

作者信息

Álvarez David Martín-Caro, Serrano-Muñoz Diego, Fernández-Pérez Juan José, Gómez-Soriano Julio, Avendaño-Coy Juan

机构信息

Toledo Physiotherapy Research Group (GIFTO), Faculty of Physiotherapy and Nursing, Castilla La Mancha University, 45071 Toledo, Spain.

出版信息

J Clin Med. 2022 Mar 25;11(7):1832. doi: 10.3390/jcm11071832.

Abstract

Former studies investigated the application of high-frequency alternating currents (HFAC) in humans for blocking the peripheral nervous system. The present trial aims to assess the effect of HFAC on the motor response, somatosensory thresholds, and peripheral nerve conduction when applied percutaneously using frequencies of 10 kHz and 20 kHz in healthy volunteers. A parallel, placebo-controlled, double-blind, randomized clinical trial was conducted. Ultrasound-guided HFAC at 10 kHz and 20 kHz and sham stimulation were delivered to the median nerve of 60 healthy volunteers for 20 min. The main assessed variables were the maximum isometric flexion strength (MFFS) of the index finger, myotonometry, pressure pain threshold (PPT), mechanical detection threshold (MDT), and sensory nerve action potential (SNAP). A decrease in the MFFS is observed immediately postintervention compared to baseline, both in the 10 kHz group (-8.5%; 95% CI -14.9 to -2.1) and the 20 kHz group (-12.0%; 95% CI -18.3 to -5.6). The between-group comparison of changes in MFFS show a greater reduction of -10.8% (95% CI -19.8 to -1.8) immediately postintervention in the 20 kHz compared to the sham stimulation group. The percutaneous stimulation applying 20 kHz HFAC to the median nerve produces a reversible postintervention reduction in strength with no adverse effects.

摘要

先前的研究调查了高频交流电(HFAC)在人体中阻断外周神经系统的应用。本试验旨在评估在健康志愿者中经皮施加频率为10 kHz和20 kHz的HFAC时,其对运动反应、躯体感觉阈值和周围神经传导的影响。进行了一项平行、安慰剂对照、双盲、随机临床试验。在60名健康志愿者的正中神经上施加10 kHz和20 kHz的超声引导下的HFAC以及假刺激,持续20分钟。主要评估变量为食指的最大等长屈曲力量(MFFS)、肌张力测量、压力疼痛阈值(PPT)、机械检测阈值(MDT)和感觉神经动作电位(SNAP)。干预后立即观察到,10 kHz组(-8.5%;95%CI -14.9至-2.1)和20 kHz组(-12.0%;95%CI -18.3至-5.6)的MFFS与基线相比均有所下降。MFFS变化的组间比较显示,与假刺激组相比,20 kHz组干预后立即出现更大幅度的降低,为-10.8%(95%CI -19.8至-1.8)。在正中神经上施加20 kHz HFAC的经皮刺激会导致干预后力量可逆性降低,且无不良影响。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验