Department of Physical Medicine and Rehabilitation in the University Hospital Center of Limoges, Limoges.
Department of Physical Medicine and Rehabilitation in the University Hospital Center of Limoges, Limoges; HAVAE UR20217 (Handicap, Aging, Autonomy, Environment), FEDRHA, University of Limoges, Limoges.
Arch Phys Med Rehabil. 2022 Nov;103(11):2245-2255. doi: 10.1016/j.apmr.2022.03.020. Epub 2022 Apr 17.
To evaluate the validity and test-retest reliability of physical activity trackers (accelerometer, multisensor, smartphone, pedometer) for estimating energy expenditure during walking in individuals with stroke.
Webline, MEDLINE, Scopus, ScienceDirect, Bielefeld Academic Search Engine, and Wiley Online Library databases from 1980 to November 2020.
The inclusion criteria were studies that examined the validity of portable physical activity trackers for estimating energy expenditure in individuals with stroke during walking activities compared to indirect calorimetry.
This systematic review was reported according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, and the methodological quality of the included studies was determined with the Quality Assessment of Diagnostic Accuracy Studies. The study selection was made by 2 blind observers.
We screened 3677 articles; 3647 were excluded after duplicate removal and title and abstract review. Thirty articles were included for full-text analysis. Eight articles met the inclusion criteria (184 individuals with stroke) and were included in the data synthesis and meta-analysis. For all monitors, activities, and placements, the overall level of correlation with indirect calorimetry was 0.34 (95% confidence interval [CI], 0.23-0.44). After subgroups analysis, we showed that type and placement have no effect on the level of validity. Test-retest reliability was high, with intraclass correlation equal to 0.89 (95% CI, 0.76-0.95).
Portable physical activity monitors provided a low correlation with indirect calorimetry during walking in individuals with stroke. It seems essential to pursue studies to improve their validity in this population.
评估计步器(加速度计、多传感器、智能手机、计步器)在评估脑卒中患者行走时能量消耗的有效性和重测信度。
1980 年至 2020 年 11 月,在线数据库 Webline、MEDLINE、Scopus、ScienceDirect、Bielefeld Academic Search Engine 和 Wiley Online Library。
纳入标准为比较计步器与间接测热法评估脑卒中患者行走时能量消耗的有效性的研究。
本系统评价按照系统评价和荟萃分析报告的首选项目进行报告,并使用诊断准确性研究质量评估来确定纳入研究的方法学质量。研究选择由 2 名盲法观察者进行。
我们筛选了 3677 篇文章;3647 篇在去除重复项和标题及摘要审查后被排除。30 篇文章进行了全文分析。8 篇文章符合纳入标准(184 名脑卒中患者),并纳入数据综合和荟萃分析。对于所有监测器、活动和位置,与间接测热法的整体相关性水平为 0.34(95%置信区间,0.23-0.44)。在亚组分析后,我们表明类型和位置对有效性水平没有影响。重测信度较高,组内相关系数等于 0.89(95%置信区间,0.76-0.95)。
在脑卒中患者行走时,便携式运动监测器与间接测热法相关性较低。似乎有必要开展研究,以提高这些监测器在该人群中的有效性。