Suppr超能文献

静态与动态计算机辅助种植手术导航系统在愈合拔牙窝和新鲜拔牙窝中种植体植入精度的比较:基于模型的评估

Comparison of Implant Placement Accuracy in Healed and Fresh Extraction Sockets between Static and Dynamic Computer-Assisted Implant Surgery Navigation Systems: A Model-Based Evaluation.

作者信息

Wang Miaozhen, Rausch-Fan Xiaohui, Zhan Yalin, Shen Huidan, Liu Feng

机构信息

First Clinical Division, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, 37 A Xishiku Street, Xicheng District, Beijing 100034, China.

Division of Conservative Dentistry and Periodontology, Center of Clinical Research, Dental School, Medical University of Vienna, 1090 Vienna, Austria.

出版信息

Materials (Basel). 2022 Apr 11;15(8):2806. doi: 10.3390/ma15082806.

Abstract

The aim of this model-base study was to compare the accuracy of implant placement between static and dynamic computer-assisted implant surgery (CAIS) systems in a fresh extraction socket and healed ridge. A randomized in vitro study was conducted. Twenty 3D-printed maxillary models and 80 implants were used. One experienced researcher placed the implants using either the static navigation or dynamic navigation system. Accuracy was measured by overlaying the real position in the postoperative CBCT on the virtual presurgical placement of the implant in a CBCT image. Descriptive and bivariate analyses of the data were performed. In the fresh sockets, the mean deviation was 1.24 ± 0.26 mm (entry point), 1.69 ± 0.34 mm (apical point), and 3.44 ± 1.06° (angle discrepancy) in the static CAIS group, and 0.60 ± 0.29 mm, 0.78 ± 0.33 mm, and 2.47 ± 1.09° in the dynamic CIAS group, respectively. In the healed ridge, the mean deviation was 1.09 ± 0.17 mm and 1.40 ± 0.30 mm, and 2.12 ± 1.11° in the static CAIS group, and 0.80 ± 0.29 mm, 0.98 ± 0.37 mm, and 1.69 ± 0.76° in the dynamic CIAS group, respectively. Compared with the static CAIS system, the dynamic CAIS system resulted in significantly lower entry and apical errors in both fresh sockets and healed ridges. Differences in bone morphology therefore seem to have little effect on accuracy in the dynamic CAIS group.

摘要

本基于模型的研究旨在比较在新鲜拔牙窝和愈合牙槽嵴中,静态和动态计算机辅助种植手术(CAIS)系统植入种植体的准确性。进行了一项随机体外研究。使用了20个3D打印的上颌模型和80颗种植体。一名经验丰富的研究人员使用静态导航或动态导航系统植入种植体。通过将术后CBCT中的实际位置与CBCT图像中种植体的虚拟术前植入位置进行叠加来测量准确性。对数据进行了描述性和双变量分析。在新鲜拔牙窝中,静态CAIS组的平均偏差为入口点1.24±0.26mm、根尖点1.69±0.34mm和角度差异3.44±1.06°,动态CIAS组分别为0.60±0.29mm、0.78±0.33mm和2.47±1.09°。在愈合牙槽嵴中,静态CAIS组的平均偏差分别为1.09±0.17mm、1.40±0.30mm和2.12±1.11°,动态CIAS组分别为0.80±0.29mm、0.98±0.37mm和1.69±0.76°。与静态CAIS系统相比,动态CAIS系统在新鲜拔牙窝和愈合牙槽嵴中的入口和根尖误差均显著更低。因此,骨形态的差异似乎对动态CAIS组的准确性影响不大。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a5b0/9030091/dc1a2cce811d/materials-15-02806-g004.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验