Suppr超能文献

脉宽和水/气冷却比对 Er:YAG 2940nm 激光去除瓷贴面粘结的影响:一项体外研究。

Influence of pulse duration and water/air cooling ratio on the efficiency of Er:YAG 2940 nm laser in debonding of porcelain laminate veneers: An in vitro study.

机构信息

Department of Prosthodontics, Faculty of Dentistry, Alsham Private University, Damascus, Syria.

Laboratory of Medical Lasers, The Higher Institute for Laser Research and Applications, Damascus University, Damascus, Syria.

出版信息

Clin Exp Dent Res. 2022 Aug;8(4):843-848. doi: 10.1002/cre2.554. Epub 2022 Apr 29.

Abstract

OBJECTIVE

To determine the effectiveness of different pulse durations (PD) and the water/air (W/A) cooling ratio of the Er:YAG 2940 nm laser that are required for debonding porcelain laminate veneers (PLV), by investigation of the needed time for PLV debonding (DT) and the changes in dental pulp temperature.

MATERIALS AND METHODS

Thirty-six extracted noncarious human maxillary premolars were prepared for receiving PLV. Samples were randomly assigned to six different groups, based on PD and the W/A ratio: Groups A (50 µs, 1:1), B (50 µs, 3:3), C (100 µs, 1:1), D (100 µs, 3:3), E (300 µs, 1:1), and F (300 µs, 3:3). Veneers were debonded using laser irradiation by the same parameters (270 mJ, 15 Hz) with noncontact application mode.

RESULTS

All 36 veneers were debonded. Samples of the 50 and 100 µs PDs showed significantly shorter DT (7.4-17 s) than that of the 300 µs which showed significantly the longest DT (104 s) among all other groups (p < .001). However, the highest elevation of pulp temperature was observed in Group E (300 µs, 1:1) which reached (3.4°C).

CONCLUSION

Using the 50 or 100 µs PD of the Er:YAG laser was more efficient than 300 µs in reducing DT of PLVs with minimal change in pulp temperature. W/A cooling ratio had minimal influence on the DT of PLV.

摘要

目的

通过研究瓷贴面剥离所需的时间(DT)和牙髓温度的变化,确定 Er:YAG 2940nm 激光不同脉冲持续时间(PD)和水/气(W/A)冷却比在剥离瓷贴面(PLV)时的有效性。

材料与方法

对 36 颗上颌前磨牙进行预备,以接收 PLV。样本根据 PD 和 W/A 比随机分为六组:A 组(50µs,1:1)、B 组(50µs,3:3)、C 组(100µs,1:1)、D 组(100µs,3:3)、E 组(300µs,1:1)和 F 组(300µs,3:3)。使用激光照射以相同的参数(270mJ,15Hz)进行剥离,采用非接触应用模式。

结果

所有 36 个贴面均成功剥离。50µs 和 100µs PD 组的 DT(7.4-17s)明显短于 300µs PD 组(所有其他组中最长的 DT 为 104s)(p<.001)。然而,在所有组中,牙髓温度升高最高的是 E 组(300µs,1:1),达到(3.4°C)。

结论

与 300µs 相比,使用 Er:YAG 激光的 50µs 或 100µs PD 可更有效地减少 PLV 的 DT,同时牙髓温度变化最小。W/A 冷却比对 PLV 的 DT 影响最小。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9ce3/9382051/85ac91ca1b54/CRE2-8-843-g003.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验