Department of Ophthalmology, Antalya Training and Research Hospital, University of Health Sciences, Antalya, Turkey.
Arq Bras Oftalmol. 2023 Oct 13;86(5):e20230069. doi: 10.5935/0004-2749.20230069. eCollection 2023.
The study aimed to evaluate the ocular surface and meibomian gland morphology in electronic cigarette (e-cigarette) smokers.
The upper and lower eyelids of 25 male e-cigarette smokers and 25 healthy male non-smoker patients were evaluated using Sirius meibography. Meibomian glands loss was automatically calculated using Phoenix meibography imaging software module, with the result obtained as percentage loss. Ocular Surface Disease Index (OSDI) questionnaire, tear breakup time test, and Schirmer II test were administered and performed in all cases.
The mean e-cigarette smoking duration was 4.9 ± 0.9 (range, 3.4-7) years. While the mean Schirmer II test value was 9.16 ± 2.09 mm in e-cigarette group, it was 11.20 ± 2.14 mm in control group (p=0.003). Mean tear breakup time was 6.96 ± 2.31 seconds in e-cigarette group and 9.84 ± 2.13 seconds in control group (p=0.002). The mean OSDI value was 28.60 ± 6.54 and 15.16 ± 7.23 in e-cigarette and control groups, respectively (p<0.001). In Sirius meibography, the average loss for the upper eyelid was 23.08% ± 6.55% in e-cigarette group and 17.60% ± 4.94% in control group (p=0.002), and the average loss for the lower eyelid was 27.84% ± 5.98% and 18.44% ± 5.91%, respectively (p<0.001). Additionally, a significant positive correlation was identified between the loss rates for both upper and lower eyelid meibography with e-cigarette smoking duration (r=0.348, p<0.013 and r=0.550, p<0.001, respectively).
Long-term e-cigarette smoking causes damage to the meibomian glands; therefore, meibomian gland damage should be considered in ocular surface disorders due to e-ci-garette smoking.
本研究旨在评估电子烟(e-cigarette)吸烟者的眼表和睑板腺形态。
使用 Sirius 睑板腺照相仪评估 25 名男性电子烟吸烟者和 25 名健康男性非吸烟者的上下眼睑。使用 Phoenix 睑板腺成像软件模块自动计算睑板腺缺失率,结果以百分比缺失表示。对所有患者进行眼表疾病指数(OSDI)问卷、泪膜破裂时间(tear breakup time,BUT)和 Schirmer II 试验。
平均电子烟吸烟时间为 4.9±0.9(范围:3.4-7)年。电子烟组的平均 Schirmer II 试验值为 9.16±2.09mm,而对照组为 11.20±2.14mm(p=0.003)。电子烟组的平均 BUT 为 6.96±2.31 秒,对照组为 9.84±2.13 秒(p=0.002)。OSDI 均值分别为 28.60±6.54 和 15.16±7.23,电子烟组和对照组分别为 28.60±6.54 和 15.16±7.23(p<0.001)。在 Sirius 睑板腺照相中,电子烟组的上眼睑平均缺失率为 23.08%±6.55%,对照组为 17.60%±4.94%(p=0.002),下眼睑平均缺失率分别为 27.84%±5.98%和 18.44%±5.91%(p<0.001)。此外,上、下睑板腺照相的缺失率与电子烟吸烟时间之间存在显著正相关(r=0.348,p<0.013 和 r=0.550,p<0.001)。
长期电子烟吸烟会导致睑板腺损伤,因此,应考虑电子烟吸烟引起的眼表疾病中的睑板腺损伤。