School of Psychology, University of Wollongong, Wollongong, Australia.
Illawarra Health and Medical Research Institute, University of Wollongong, Wollongong, NSW, 2522, Australia.
Sci Rep. 2022 May 11;12(1):7775. doi: 10.1038/s41598-022-11755-y.
Inconsistencies have been found in the relationship between ambient lighting conditions and frequency-dependence in transcranial electric stimulation (tES) induced phosphenes. Using a within-subjects design across lighting condition (dark, mesopic [dim], photopic [bright]) and tES stimulation frequency (10, 13, 16, 18, 20 Hz), this study determined phosphene detection thresholds in 24 subjects receiving tES using an FPz-Cz montage. Minima phosphene thresholds were found at 16 Hz in mesopic, 10 Hz in dark and 20 Hz in photopic lighting conditions, with these thresholds being substantially lower for mesopic than both dark (60% reduction) and photopic (56% reduction), conditions. Further, whereas the phosphene threshold-stimulation frequency relation increased with frequency in the dark and decreased with frequency in the photopic conditions, in the mesopic condition it followed the dark condition relation from 10 to 16 Hz, and photopic condition relation from 16 to 20 Hz. The results clearly demonstrate that ambient lighting is an important factor in the detection of tES-induced phosphenes, and that mesopic conditions are most suitable for obtaining overall phosphene thresholds.
在环境光照条件与经颅电刺激(tES)诱导的闪光幻觉之间的频率相关性中发现了不一致。本研究采用单被试设计,在光照条件(黑暗、中间视[昏暗]、明视[明亮])和 tES 刺激频率(10、13、16、18、20 Hz)之间,使用 FPz-Cz 导联记录了 24 名受试者接受 tES 时的闪光幻觉检测阈值。在中间视条件下,闪光幻觉检测阈值在 16 Hz 时最小,在黑暗条件下在 10 Hz 时最小,在明视条件下在 20 Hz 时最小,与黑暗条件(降低 60%)和明视条件(降低 56%)相比,这些阈值明显更低。此外,在黑暗条件下,闪光幻觉阈值-刺激频率关系随频率增加而增加,在明视条件下随频率降低而降低,而在中间视条件下,它遵循从 10 到 16 Hz 的黑暗条件关系,以及从 16 到 20 Hz 的明视条件关系。研究结果清楚地表明,环境光照是检测 tES 诱导的闪光幻觉的一个重要因素,中间视条件最适合获得整体闪光幻觉阈值。