通过前段光学相干断层扫描评估光照条件和调节对可植入有晶状体眼接触镜拱高的影响。

Effect of Light Conditions and Accommodation on Implantable Phakic Contact Lens Vault by Anterior Segment Optical Coherence Tomography.

作者信息

Mahmoud Mohamed Salah El-Din, AbdelHalim Ahmed Shawkat, Zein Hosny Ahmed

机构信息

Ophthalmology Department, Faculty of Medicine, Minia University, Minia, Egypt.

出版信息

Clin Ophthalmol. 2022 May 5;16:1439-1447. doi: 10.2147/OPTH.S359296. eCollection 2022.

Abstract

PURPOSE

To investigate the dynamic pupil and vault changes in eyes with implantable phakic contact lens (IPCL) under photopic and scotopic settings, as well as during accommodation using the anterior segment optical coherence tomography (AS-OCT).

METHODS

A prospective observational study included consecutive 36 eyes of myopic patients who underwent IPCL V2.0 implantation. Under photopic and scotopic light settings, as well as during accommodation, all patients were scanned using CASIA OCT (CASIA2; TOMEY, Nagoya, Japan). The pupil size, the vault (distance between the back surface of the IPCL and the anterior lens capsule), ACD-lens (distance between the posterior corneal surface and the anterior lens surface), IPCL-lens (distance between the posterior corneal surface and the anterior IPCL surface), and lens thickness (LT) were the study parameters.

RESULTS

The vault was significantly lower under photopic conditions (-value<0.001). The pupil size was significantly smaller in photopic conditions (-value<0.001). LT (-value=0.975) and ACD-lens (-value=0.917) were not significantly different between scotopic and photopic conditions, while the ACD-IPCL was significantly larger during photopic conditions (-value=0.013). There were significant changes in all parameters between accommodative and non-accommodative conditions.

CONCLUSION

The IPCL vault decreased significantly under photopic light conditions and accommodation.

摘要

目的

使用眼前节光学相干断层扫描(AS-OCT)研究植入可植入式有晶状体眼接触镜(IPCL)的眼睛在明视和暗视条件下以及调节过程中的动态瞳孔和房拱变化。

方法

一项前瞻性观察性研究纳入了连续36只接受IPCL V2.0植入的近视患者的眼睛。在明视和暗视光照条件下以及调节过程中,所有患者均使用CASIA OCT(CASIA2;日本名古屋TOMEY公司)进行扫描。研究参数包括瞳孔大小、房拱(IPCL后表面与晶状体前囊膜之间的距离)、ACD-晶状体(角膜后表面与晶状体前表面之间的距离)、IPCL-晶状体(角膜后表面与IPCL前表面之间的距离)以及晶状体厚度(LT)。

结果

在明视条件下房拱显著更低(P值<0.001)。在明视条件下瞳孔大小显著更小(P值<0.001)。暗视和明视条件下LT(P值=0.975)和ACD-晶状体(P值=0.917)无显著差异,而在明视条件下ACD-IPCL显著更大(P值=0.013)。调节和非调节条件下所有参数均有显著变化。

结论

在明视光照条件和调节状态下,IPCL房拱显著降低。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/67b5/9084507/8c75e81e387a/OPTH-16-1439-g0001.jpg