瞳孔散大对植入可植入式角膜接触镜V4和V4c的中高度近视眼睛的影响。

The effect of mydriasis on moderate-to-high myopic eyes with implantable collamer lenses V4 and V4c.

作者信息

Zhu Yi, Zhang Jing, Zhu Haobin, Chen Jili, Zhou Jibo

机构信息

Department of Ophthalmology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.

Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China.

出版信息

Eur J Ophthalmol. 2020 May;30(3):462-468. doi: 10.1177/1120672119831218. Epub 2019 Mar 8.

Abstract

PURPOSE

To evaluate the vault change and anterior segment movement induced by mydriasis in moderate-to-high myopic eyes with implantable collamer lenses (ICL).

SETTING

Shanghai, China.

DESIGN

A prospective consecutive observational study.

METHODS

A total of 45 eyes of 24 patients with ICL V4 implantation and 128 eyes of 65 patients with ICL V4c implantation were included and analyzed. Anterior chamber depth, posterior corneal endothelium-to-ICL distance, and vault before and after mydriasis were measured by Pentacam (Oculus, Wetzlar, Germany) at 1, 3, and 6 months after surgery.

RESULTS

Significant vault increases and anterior chamber depth increases induced by mydriasis were noted in both ICL V4 and V4c groups at 1, 3, and 6 months postoperatively. The corneal endothelium-ICL distance increased significantly in eyes with implanted ICL V4c after mydriasis at 3 and 6 months. Moreover, mydriasis-induced vault increases were greater in the ICL V4 group than in the ICL V4c group at 3 and 6 months. In eyes with implanted ICL V4c, mydriasis-induced vault increases were significantly greater at 1 month than at 3 and 6 months.

CONCLUSION

Mydriasis results in a general vault increase in eyes with implanted ICLs. The adjustment of the pressure equilibrium via the central hole of the ICL V4c has an important role in vault change. The mydriasis-induced vault increases tend toward stability after 3 months postoperatively. Mydriasis is relatively safe in eyes with ICL implantation.

摘要

目的

评估植入可植入式角膜接触镜(ICL)的中高度近视眼中散瞳引起的房角变化和眼前节运动。

地点

中国上海。

设计

前瞻性连续观察研究。

方法

纳入并分析了24例植入ICL V4的患者的45只眼和65例植入ICL V4c的患者的128只眼。术后1、3和6个月,使用Pentacam(德国韦茨拉尔奥culus公司)测量散瞳前后的前房深度、后角膜内皮至ICL距离和房角。

结果

术后1、3和6个月,ICL V4组和V4c组散瞳均引起房角显著增加和前房深度增加。植入ICL V4c的眼在散瞳后3个月和6个月时角膜内皮-ICL距离显著增加。此外,在3个月和6个月时,ICL V4组散瞳引起的房角增加大于ICL V4c组。在植入ICL V4c的眼中,散瞳引起的房角增加在1个月时显著大于3个月和6个月时。

结论

散瞳导致植入ICL的眼房角普遍增加。通过ICL V4c的中心孔调节压力平衡在房角变化中起重要作用。散瞳引起的房角增加在术后3个月后趋于稳定。散瞳在植入ICL的眼中相对安全。