在正常血压清醒犬中,与兽医高清振荡法相比,使用腕式血压计进行动脉血压测量。

Use of a human wrist blood pressure monitor for arterial blood pressure measurements in normotensive conscious dogs in comparison to veterinary high-definition oscillometry.

机构信息

San Francesco Veterinary Hospital, Milan, Italy.

Computer Science Department, University of Milan, Milan, Italy.

出版信息

Vet Med Sci. 2022 Jul;8(4):1429-1433. doi: 10.1002/vms3.817. Epub 2022 May 13.

Abstract

BACKGROUND

The gold standard in canine blood pressure (BP) measurement is the invasive method; however, non-invasive blood pressure measurement techniques (NIBP) are more commonly used. The lack of small, lightweight, cheap, fast and portable NIBP still remains a point to improve in the emergency setting.

KEY FINDINGS

A human wrist blood pressure (WBP) device was evaluated in comparison with the veterinary high-definition oscillometry (HDO) in conscious normotensive dogs. Systolic and diastolic BPs were evaluated in two groups of dogs. The bias, the limits of agreement and correlation between variables were calculated. Twenty-five and 36 dogs were, respectively, included in Study No. 1 (dogs weighting ≥10 kg) and 2 (dogs weighting ≥20 kg). In both studies, correlation between the two devices was moderate. A better agreement was displayed for diastolic pressure and poor precision for both systolic and diastolic pressures measurements (as determined by wide limits of agreement). The WBP method underestimated both the systolic and diastolic BP with respect to the HDO method. The inclusion of bigger dogs (Study No. 2) with limb circumference more like to human limb dimension did not improve the agreement between considered methods.

SIGNIFICANCE

The human WBP monitor considered is not suitable to replace the commonly used veterinary HDO for in-clinic BP monitoring in normotensive conscious dogs.

摘要

背景

犬血压(BP)测量的金标准是有创方法;然而,无创血压测量技术(NIBP)更为常用。在紧急情况下,缺乏小型、轻便、廉价、快速且便携的 NIBP 仍然是需要改进的一点。

主要发现

在清醒的正常血压犬中,评估了一种人类腕部血压(WBP)设备与兽医高清振荡法(HDO)的比较。在两组犬中评估了收缩压和舒张压。计算了偏倚、一致性界限和变量之间的相关性。第 1 项研究(体重≥10kg 的犬)和第 2 项研究(体重≥20kg 的犬)分别纳入了 25 只和 36 只犬。在这两项研究中,两种设备之间的相关性为中度。舒张压的一致性较好,而收缩压和舒张压的测量精度较差(表现为较宽的一致性界限)。WBP 方法相对于 HDO 方法低估了收缩压和舒张压。纳入肢围更接近人类肢体尺寸的较大型犬(研究 2)并没有改善所考虑方法之间的一致性。

意义

所考虑的人类 WBP 监测器不适合替代常用的兽医 HDO,用于正常血压、清醒犬的临床 BP 监测。

相似文献

3
Evaluation of oscillometric and Doppler ultrasonic devices for blood pressure measurements in anesthetized and conscious dogs.
Res Vet Sci. 2014 Aug;97(1):111-7. doi: 10.1016/j.rvsc.2014.05.003. Epub 2014 May 15.
7
Comparison of ultrasonic Doppler flow monitor, oscillometric, and direct arterial blood pressure measurements in ill dogs.
J Vet Emerg Crit Care (San Antonio). 2010 Apr 1;20(2):207-15. doi: 10.1111/j.1476-4431.2010.00520.x.
8
Accuracy and precision of oscillometric blood pressure in standing conscious horses.
J Vet Emerg Crit Care (San Antonio). 2016 Jan-Feb;26(1):85-92. doi: 10.1111/vec.12411. Epub 2015 Oct 21.

本文引用的文献

2
Evaluation of the relationship between peripheral pulse palpation and Doppler systolic blood pressure in dogs presenting to an emergency service.
J Vet Emerg Crit Care (San Antonio). 2018 May;28(3):226-231. doi: 10.1111/vec.12718. Epub 2018 Apr 16.
3
ISFM Consensus Guidelines on the Diagnosis and Management of Hypertension in Cats.
J Feline Med Surg. 2017 Mar;19(3):288-303. doi: 10.1177/1098612X17693500.
5
Effect of body position on indirect measurement of systolic arterial blood pressure in dogs.
J Am Vet Med Assoc. 2013 Jun 1;242(11):1523-7. doi: 10.2460/javma.242.11.1523.
6
Comparison of high definition oscillometric and Doppler ultrasound devices with invasive blood pressure in anaesthetized dogs.
Vet Anaesth Analg. 2013 Jan;40(1):21-7. doi: 10.1111/j.1467-2995.2012.00774.x. Epub 2012 Sep 24.
8
Guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats.
J Vet Intern Med. 2007 May-Jun;21(3):542-58. doi: 10.1892/0891-6640(2007)21[542:gftiea]2.0.co;2.
9
Wrist blood pressure overestimates blood pressure measured at the upper arm.
Blood Press Monit. 2004 Apr;9(2):77-81. doi: 10.1097/00126097-200404000-00004.
10
Arterial blood pressure measurement in a population of healthy geriatric dogs.
J Am Anim Hosp Assoc. 2000 Nov-Dec;36(6):497-500. doi: 10.5326/15473317-36-6-497.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验