Longitudinal passive cough monitoring and its implications for detecting changes in clinical status.

作者信息

Gabaldón-Figueira Juan C, Keen Eric, Rudd Matthew, Orrilo Virginia, Blavia Isabel, Chaccour Juliane, Galvosas Mindaugas, Small Peter, Grandjean Lapierre Simon, Chaccour Carlos

机构信息

Dept of Microbiology and Infectious Diseases, Clinica Universidad de Navarra, Pamplona, Spain.

Research and Development Dept, Hyfe Inc, Wilmington, DE, USA.

出版信息

ERJ Open Res. 2022 May 16;8(2). doi: 10.1183/23120541.00001-2022. eCollection 2022 Apr.

Abstract

RESEARCH QUESTION

What is the impact of the duration of cough monitoring on its accuracy in detecting changes in the cough frequency?

MATERIALS AND METHODS

This is a statistical analysis of a prospective cohort study. Participants were recruited in the city of Pamplona (Northern Spain), and their cough frequency was passively monitored using smartphone-based acoustic artificial intelligence software. Differences in cough frequency were compared using a one-tailed Mann-Whitney U test and a randomisation routine to simulate 24-h monitoring.

RESULTS

616 participants were monitored for an aggregated duration of over 9 person-years and registered 62 325 coughs. This empiric analysis found that an individual's cough patterns are stochastic, following a binomial distribution. When compared to continuous monitoring, limiting observation to 24 h can lead to inaccurate estimates of change in cough frequency, particularly in persons with low or small changes in rate.

INTERPRETATION

Detecting changes in an individual's rate of coughing is complicated by significant stochastic variability within and between days. Assessing change based solely on intermittent sampling, including 24-h, can be misleading. This is particularly problematic in detecting small changes in individuals who have a low rate and/or high variance in cough pattern.

摘要

研究问题

咳嗽监测时长对检测咳嗽频率变化准确性的影响是什么?

材料与方法

这是一项前瞻性队列研究的统计分析。参与者在西班牙北部潘普洛纳市招募,使用基于智能手机的声学人工智能软件被动监测他们的咳嗽频率。使用单尾曼-惠特尼U检验和随机程序比较咳嗽频率差异,以模拟24小时监测。

结果

对616名参与者进行了总计超过9人年的监测,记录到62325次咳嗽。该实证分析发现,个体的咳嗽模式是随机的,遵循二项分布。与连续监测相比,将观察限制在24小时可能导致对咳嗽频率变化的估计不准确,尤其是在咳嗽频率变化较小或变化率较低的人群中。

解读

个体咳嗽频率的显著随机变异性使得检测个体咳嗽频率变化变得复杂。仅基于间歇性采样(包括24小时采样)来评估变化可能会产生误导。在检测咳嗽频率低和/或咳嗽模式方差高的个体中的微小变化时,这一问题尤为突出。